Fatigue Behavior of Composite Beams with Pyramidal Shear Connector

입체트러스형 전단연결재를 갖는 합성판의 피로거동

  • 이경동 (순천대학교 토목환경공학부) ;
  • 한재익 (서남대학교 토목공학과)
  • Received : 2002.01.30
  • Published : 2002.04.30

Abstract

A steel plate-concrete composite slab with pyramidal shear connectors, named TSC composite slab, is expected to have sufficient bending strength and flexural rigidity for loads during and after construction. Fatigue problems play an important role in designing composite slab as bridge decks under traffic conditions. In this paper, a series of fatigue tests was carried out on TSC beam specimens under various loading conditions, in order to evaluate the fatigue strength of TSC composite slabs. The results are as follows : (1) the fatigue failure of TSC composite beams results from the tensile fracture of bottom steel plate and shear connector, and (2) fatigue strength of the steel plate for two million cycles can be estimated to be $1144kgf/cm^2$ from the S-N curves.

Keywords