On the Effect and Design of Diffusing Aerator for Thermal De-stratification

산기장치를 이응한 호수의 성층파괴효과와 설계

  • 송무석 (홍익대학교 조선해양공학과) ;
  • 서동일 (충남대학교 환경공학과)
  • Published : 2002.08.01

Abstract

The effect and the overall optimal operation of artificial aeration devices for mixing of thermally stratified water reservoir are under study, and its brief introduction is made. The study site is Yeoncho Lake in Geojae island, which is well known for its eutrophication problems in the summer. A few samplings have been made before and after the operation of two types of artificial aerators, and the effect is believed to be positive. Also, design methodology for such artificial aerators is reviewed and a few are applied to the case of Yeoncho Lake. Schladow's[1993] proposal is believed most proper based on the information we have gathered by now. In addition, a simple numerical experiment is also peformed to see the overall effect of the device on the flow and temperature profile.

호수의 온도성층 파기를 위하여 이용되는 수체순환용 공기공급장치의 효과와 최적운용방법에, 거제도의 연초호의 경우에 초점을 맞추어 살펴보았다. 폭기장치의 효과를 가동 전후의 수질을 평가함으로써 고찰하였고 Schladow[1993]의 방법에 기초한 산기장치의 최적설계법 또한 연초호의 상태와 비교를 통하여 제안하였다 전반적인 혼합효과의 파악을 위하여 단순화된 수체모델에 대한 모사시험도 수행하였다 연초호의 경우 폭기장치의 효과가 나타나는 것으로 판단된다.

Keywords