Journal of ILASS-Korea (한국분무공학회지)
- Volume 7 Issue 4
- /
- Pages.9-15
- /
- 2002
- /
- 1226-2277(pISSN)
- /
- 2288-9051(eISSN)
Tomographic reconstruction of Asymmetric Spray by Direct Sampling Method
직접샘플링에 의한 비대칭 분무의 토모그래피 재구성
Abstract
Convolution Fourier transformation tomographically reconstructs the spatially resolved spray injection rate from direct measuring cells. Asymmetric sprays generated from a twin-hole air shroud injector are tested with 12 equiangular projections of measurements. For each projection angle, line of sight integrated injection rate was measured at 35 positions with equal spacing measuring cells of 3 mm in width, 100 mm in length, 55 mm in depth and 0.5 mm thickness of separating wall. Interpolated data between the projection angles effectively increase the number of projections, which significantly enhances the signal-to-noise level in the reconstructed data. This modified convolution Fourier transformation scheme predicts well the structure of asymmetric sprays. Comparative study has been made between sprays with and without air shrouding. Tomograhpic reconstruction of injection rate from direct measuring cells obtained can be used to estimate the accuracy of volume fraction of spray from the LDPA tomographic reconstruction.
Keywords