Position Analysis of Cow Teats for Teat-cup Attachment System on Robotic Milking System

로봇 착유기의 착유컵 자동착탈을 위한 착유우의 유두위치 조사분석

  • Kwon, D.J. (National Livestock Research Institute) ;
  • Kim, W. (Department of Bio-mechatronics SungKyunKwan University) ;
  • Lee, D.W. (Department of Bio-mechatronics SungKyunKwan University)
  • 권두중 (축산기술연구소) ;
  • 김웅 (성균관대학교 바이오메카트로닉스학과) ;
  • 이대원 (성균관대학교 바이오메카트로닉스학과)
  • Published : 2002.12.01

Abstract

The distance between teats of each head on twenty heads of holstein was measured in Nation Livestock Research Institute of Rural Development Administration to find design variables on the teat-cup attachment system of the auto-milking system before milking. The distance between teats was tested by the steps for milk producing in the morning and evening. The results from this study is summarized as follow. 1 The maximum and minimum length between front teats were 297mm and 112mm respectively, the maximum and minimum length between rear teats were 231mm and 36mm and the maximum and minimum length between left front and left rear were 220 and 84mm. And the maximum length of right front and right rear were 205mm and 90mm. A relative position of the each teats was asymmetric. 2. The size of teats, the length between front teats, and the length between rear teats by lactating period were very much changed for its milking. 3. The design variables on the teat-cup attachment system was found by the length between each teats tested. Since the position of teat-cup is changed by milking environment for a cow to milk, the design variables should be considered to be asymmetric area between four teat of COW.

Keywords