DOI QR코드

DOI QR Code

중합광원과 레진 색상이 복합레진의 중합깊이에 미치는 영향

EFFECT OF LIGHT SOURCE AND SHADE ON DEPTH OF CURE OF COMPOSITES

  • 나준석 (전남대학교 치과대학 보존학교실, 치의학 연구소) ;
  • 정선와 (서남대학교 의과대학 치과학교실) ;
  • 황윤찬 (전남대학교 치과대학 보존학교실, 치의학 연구소) ;
  • 김선호 (전남대학교 치과대학 보존학교실, 치의학 연구소) ;
  • 윤창 (전남대학교 치과대학 보존학교실, 치의학 연구소) ;
  • 오원만 (전남대학교 치과대학 보존학교실, 치의학 연구소) ;
  • 황인남 (전남대학교 치과대학 보존학교실, 치의학 연구소)
  • Na, Joon-Sok (Dept. of Conservative Dentistry, College of Dentistry, DSRI, Chonnam National University) ;
  • Jeong, Sun-Wa (Dept. of Dentistry, College of Medicine, Seonam University) ;
  • Hwang, Yun-Chan (Dept. of Conservative Dentistry, College of Dentistry, DSRI, Chonnam National University) ;
  • Kim, Sun-Ho (Dept. of Conservative Dentistry, College of Dentistry, DSRI, Chonnam National University) ;
  • Yun, Chang (Dept. of Conservative Dentistry, College of Dentistry, DSRI, Chonnam National University) ;
  • Oh, Won-Mann (Dept. of Conservative Dentistry, College of Dentistry, DSRI, Chonnam National University) ;
  • Hwang, In-Nam (Dept. of Conservative Dentistry, College of Dentistry, DSRI, Chonnam National University)
  • 발행 : 2002.11.01

초록

Purpose of this research is estimating polymerization depth of different source of light. XL 3000 for halo-gen light, Apollo 95E for plasma arc light and Easy cure for LED light source were used in this study. Different shade (B1 & A3) resin composites (Esthet-X, Dentsply, U.S.A.) were used to measure depth of cure. 1, 2, and 3 mm thick samples were light cured for three seconds, six seconds or 10 seconds with Apollo 95E and they were light cured with XL-3000 and Easy cure for 10 seconds, 20 seconds, or 40 seconds. Vicker's hardness test carried out after store samples for 24 hours in distilled water. Results were as following. 1. Curing time increases from al1 source of lights, oui$.$ing depth increased(p<0.05). 2. Depth (that except 1mm group and 2mm group which lighten to halogen source of light) deepens in all groups, Vickers hardness decreased(p<0.05). 3. Vicker's hardness of A3 shade composite was lower in all depths more than B1 shade composites in group that do polymerization for 10 seconds and 20 seconds using halogen source of light(p<0.05), but group that do polymerization lot 40 seconds did not show difference(p>0.05). 4. Groups that do polymerization using Plasma arc and LED source of light did not show Vicker's hardness difference according to color at surface and 1mm depth(p>0.05), but showed difference according to color at 2mm and 3mm depth(p<0.05). The results showed that Apollo 95E need more polymerization times than manufacturer's recommendation (3 seconds), and Easy cure need polymerization time of XL-3000 at least.

키워드

참고문헌

  1. Stephen C, Bayne MS, Harald O, Heymann HO, Edward J, Swift JR. : Update on dental composite restorations. J Am Dent Assoc 125:687-701, 1994 https://doi.org/10.14219/jada.archive.1994.0113
  2. Mills RW. Jandt KD : Blue LEDs for curing polymerbased dental filling materials. LEOS Newsletter 12:9-10. 1998
  3. Shintani H, Inoue T, Yamaki M : Analysis of camphorquinone in visible light cured composite resins. Dent Mat 1:14-126. 1985
  4. Peutzfeldt A, Asmussen E : Hardness of restorative resins: effect of camphorquinone, amine. and inhibitor. ACTA Odontol Scand 47:229-231, 1989 https://doi.org/10.3109/00016358909007706
  5. Fan PL, Wozniak WT, Reyes WD, Stanford JW : Irradiance of visible light-curing units and voltage variation effects. J Am Dent Assoc 115:442-445, 1987 https://doi.org/10.14219/jada.archive.1987.0252
  6. Rueggeberg FA. Caughman WF : Factors affecting light transmission of single-use, plastic light-curing tips. Oper Dent 23:179-184, 1998
  7. Pouls JG. Styner DL : Curing lights: Changes in intensity output with use over time. General Dent January-February 70-73, 1997
  8. Pilo R, Oelgiesser D, Cardash HS : A survey of intensity and potential for depth of cure among light-curing units in clinical use. J Dent 27:235-241, 1999 https://doi.org/10.1016/S0300-5712(98)00052-9
  9. Peutzfeldt A, Sahafi A, Asmussen E : Characterization of resin composites polymerized with plasma arc curing units. Dent Mater 19:330-336, 2000
  10. Munksgaard EC, Peutzfeldt A, Asmussen E : Elution of TEGDMA and BisGMA from a resin and a resin composite cured with halogen or plasma light. Eur J Oral Sci 108:341-345. 2000 https://doi.org/10.1034/j.1600-0722.2000.108004341.x
  11. Clinical research associates newsletter volume 23. Issue 5-6, May-June, 1999
  12. Pearson GJ, Longman CM : Water sorption and solubility of resin-based materials following inadequate polymerization by a visible-light curing system. J Oral Rehabil 16:57-61. 1989
  13. Eakle WS : Fracture resistance of teeth restored with class II bonded composite resin. J Dent Res 65: 149-153, 1986 https://doi.org/10.1177/00220345860650021201
  14. Youngson CC. Glyn Jhones JC, Fox K, Smith IS, Wood DJ. Gale M : A fluid filtration and clearing techneque to assess microleakage associated with three dentine bonding systems. J Dent 27:223-233, 1999 https://doi.org/10.1016/S0300-5712(98)00048-7
  15. Tsunekawa M. Setcos JC. U.S.A.mi Y. Iwaku M, Marshall SJ : A new light-activated adhesive composite: shear bond strength and microleakage. Dent Mater 8:234-237, 1992 https://doi.org/10.1016/0109-5641(92)90091-P
  16. Rueggeberg FA, Caughman, WF, Curtis JW : Effect of light intensity and exposure duration on cure of resin composites. Oper Dent 19:26-32, 1994
  17. Pires JAF, Cvitko E. Denehy G, Swift EJ Jr : Effect of curing tip distance on light intersity and composite resin microhardness . Quintessence int 24:517-521, 1993
  18. Davidson-Kaban SS, Davidson CL, Feilzer AJ, Gee AJ, Erdilek N : The effect of curing light variations on bulk curing and wall-to-wall quality of two types and various shades of resin composites. Dent Mater 13:344-52, 1997
  19. Vargas MA, Cobb DS, Schmit JL : Polymerization of composite resins: Argon laser vs conventional light. Oper Dent 23:87-93, 1998
  20. Vankerckhoven H, Lambrechts P, Vanbeylen M. Davidson CL, Vanherle G : Unreated methacrylate groups on the surfaces of composite resins. J Dent Res 61 :791-796, 1982
  21. Tanoue N, Matsumura H, Atsuta M : Curing depth of prosthetic composite materials polymerized with their proprietary photo-curing units. J Oral Rehabil 26:594-599, 1999 https://doi.org/10.1046/j.1365-2842.1999.00408.x
  22. Kawaguchi M, Fukushima T, Miyazaki M : The relationship between cure depth and transmission coeffecient of visible-light-activated resin composites. J Dent Res 73:516-521, 1994
  23. Wassell RW, McCabe JF, Walls AW : Subsurface deformation associated with hardness measurements of composites. Dent Mater 8:218-223. 1992
  24. Pilo R, Cardash HS : Post-irradition polymerization of different anterior and posterior visible light-activated resin composites. Dent Mater 8:299-304, 1992 https://doi.org/10.1016/0109-5641(92)90104-K
  25. Chung KH. Greener EH : Correlation between degree of conversion. filler concentration and mechanical properities of posterior composite resins. J Oral Rehabil 17:487-494, 1990 https://doi.org/10.1111/j.1365-2842.1990.tb01419.x
  26. Harrington E, Wilson HJ : Depth of cure of radiationactivated materials: Effect of mould material and cavity size. J Dent 21:305-311.1993
  27. Jandt KD. Mills RW. Flackwell GB, Ashworth SH : Depth of cure and compressive strength of dental composites cured with blue light emitting diodes(LEDs). Dent Mater 16:41-47, 2000 https://doi.org/10.1016/S0109-5641(99)00083-4
  28. Yap AUJ, Seneviratne C : Influence of light energy density effectiveness of composite cure. Oper Dent 26, 460-466, 2001
  29. Lloyd CH, Scrimgeour SN, Chudek JA, Mackay R,. Hunter G, Pananalkis D, Abel EW : Determination of the depth of cure for VLC composites by nuclear magnetic restoration microimaging. Dent Mater 10:128-133. 1994
  30. Ferracane JL. Aday P, Matsumoto H, Marker VA : Relationship between shade and depth of cure for light-activated dental composite resins. Dent Mater 2:80-84. 1986.
  31. Shortall AC, Wilson HJ, Harrington E : Depth of cure of radiation-activated composite restoratives-influence of shade and opacity. J Oral Rehabil 22:337-342, 1995 https://doi.org/10.1111/j.1365-2842.1995.tb00782.x
  32. Warren K : An investigation into the microhardness of a light cured composite when cured through varying thicknesses of porcelain. J Oral Rehabil 17:327-334. 1990
  33. Sharkey S, Ray N, Burke F, Ziada H, Hannigan A : Surface hardness of light-activated resin composites cured by two different visible-light sources: An in vitro study. Quintessence int 32:401-405. 2001
  34. Kurachi C, Tuboy AM, Magalhaes DV, Bagnato VS : Hardness evaluation a dental composite polymerize with experimental LED-based devices. Dent Mater 17:309-315. 2001

피인용 문헌

  1. Power density of light curing units through resin inlays fabricated with direct and indirect composites vol.35, pp.5, 2010, https://doi.org/10.5395/JKACD.2010.35.5.353