DOI QR코드

DOI QR Code

전자기유량계를 이용한 기포 및 슬러그 유동 측정방법 연구

Flow Measurement in Bubbly and Slug Flow Regimes Using The Electromagnetic Flowmeter Developed

  • 차재은 (포항공과대학교 기계공학과) ;
  • 안예찬 (포항공과대학교 대학원 기계공학과) ;
  • 서경우 (포항공과대학교 대학원 환경공학부) ;
  • 김무환 (포항공과대학교 긱계공학과)
  • 발행 : 2002.11.01

초록

In order to investigate the characteristics of electromagnetic flowmeter in two -phase flow, an AC electromagnetic flowmeter was designed and manufactured. In various flow conditions, the signals and noises from the flowmeter were obtained and analyzed by comparison with the observed flow patterns with a high speed CCD camera. The experiment with the void simulators in which rod shaped non-conducting material was used was carried out to investigate the effect of the bubble position and the void fraction on the flowmeter. Based on the results from the void simulator, two -phase flow experiments encompassed from bubbly to slug flow regime were conducted. The simple relation $\Delta$ $U_{TP}$ = $\Delta$ $U_{SP}$ (l-$\alpha$) was verified with measurements of the potential difference and the void fraction. Due to the lack of homogeneity in a rent two -phase flow, the discrepancy between the relation and the present measurement was slightly increased with void fraction and also liquid volumetric flux jf. Whereas there is no difference in the shape of the raw signal between single-phase flow and bubbly flow, the signal amplitude for bubbly flow is higher than that for single -phase flow at the same water flow rate, since the passage area of the water flow is reduced. In the case of slug flow, the phase and the amplitude of the flowmeter output show dramatically the flow characteristics around each slug bubble and the position of a slug bubble itself. Therefore, the electromagnetic flowmeter shows a good possibility of being useful for identifying the flow regimes.ul for identifying the flow regimes.

키워드

참고문헌

  1. Kuromori, K., Nishiyama, K., Okada, T. and Ohta, H., 1992, 'New Magnetic Flowmeter with Dual Frequency Excitation-ADMAG,' Yokogawa Technical Report, No. 14, 34-42
  2. Shercliff, J.A., 1954, 'Relation Between the Velocity Profile and the Sensitivity of Electromagnetic Flowmeters,' J. Applied Physics,25,817-818 https://doi.org/10.1063/1.1721749
  3. Bevir, M.K., 1970, 'The Theory of Induced Voltage Electromagnetic Flowmeters,' J. Fluid Mechanics, 43, Part 3, 577-590 https://doi.org/10.1017/S0022112070002586
  4. Hori, M., Kobori, T. and Ouchi, Y., 1966, 'Method for Measuring Void Fraction by Electromagnetic Flowmeters,' Nippon Genshiryoku Kenkyuho (Rep.), JAERI,No. 1111
  5. Hemp, J., 1991, 'Theory of Eddy Currents in Electromagnetic Flowmeters,' Phys. D: Appl. Phys., 24,244-251 https://doi.org/10.1088/0022-3727/24/3/004
  6. Hemp, J., 2001, 'A Technique for Low Cost Calibration of Large Electromagnetic Flowmeters, Flow Measurement and Instrumentation', 12, 123-134 https://doi.org/10.1016/S0955-5986(01)00006-1
  7. Bernier, R.N. and Brennen, C.E., 1983, 'Use of The Electromagnetic Flowmeter in a Two-Phase Flow,' Int. J. Multiphase Flow,9,No.3,251-257 https://doi.org/10.1016/0301-9322(83)90104-0
  8. Bernier, R., 1981, 'Unsteady Two-Phase Flow Instrumentation and Measurement,' Ph.D. Thesis, California Institute of Technology, Pasadena, California
  9. Wyatt, D.G., 1986, 'Electromagnetic Flowmeter Sensitivity with Two-Phase Flow,' Int. J. Multiphase Flow,12,No.6, 1009-1017 https://doi.org/10.1016/0301-9322(86)90040-6
  10. Bevir, M.K., 1971, 'The Predicted Effects of Red Blood Cells on Electromagnetic Flowmeter Sensitivity,' J. Physics D: Applied Physics, 4, 387-399 https://doi.org/10.1088/0022-3727/4/3/307
  11. Velt, I.D., Petrushaitis, V.I., Sprjgin, B.S., Krasilnikov, I.V., Mikhailov, Yu.V., and Tuleninov, V.R., 1982, 'Correlation Technique for Flow Rate Measurement of Electroconductive Fluids and Two-Phase Media and Device for Its Implementation ,' (Patent No. 30.01.82)
  12. Murakami, M., Maruo, K. and Yoshiki, T., 1990, 'Development of an Electromagnetic Flowmeter for Studying Gas-Liquid, Two-Phase Flow,' International Chemical Engineering, 30,No.4, 699-702
  13. Krafft, R., 1993, 'Electromagnetic Flowmeters in Multiphase Flows,' Ph.D. Thesis, Cranfield Inst. of Technology
  14. Shercliff, J.A., 1962, 'The Theory of Electromagnetic Flow Measurement,' Cambridge University Press
  15. Lunta, E. and Halttunen, J., 1989, 'The Effect of Velocity Profile on Electromagnetic Flow Measurement,' Sensor and Actuator,16,335-344
  16. Lockhart R.W. and Martinelli R.C., 1949, 'Proposed Correlation of Data for Isothermal Two-Phase, Two-Component Flow in Pipes,' Chemical Engineering Progress, 45,No.1,39-48
  17. Georges E. Smissaert, 1963, 'Two-Component Two-Phase Flow Parameters for Low Circulation Rates,'ANL-6755,July
  18. Watanabe, M., 1977, 'Noise Compensation in Electromagnetic Flowmeter,' US Patent 4,019,385
  19. James, W.G., 1951, 'An Induction Flowmeter Design Suitable for Radioactive Liquids,' The Review of Scientific Instruments,22,N.12,989-1002 https://doi.org/10.1063/1.1745841