서로 다른 표면특성을 갖는 핀-관 열교환기의 착상과 제상 성능평가

The Frost and Defrost Performances of Fin-and-Tube Heat Exchangers with Different Surface Treatment Characteristics

  • 최봉준 (LG전자 디지털 어플라이언스 사업본부 연구소) ;
  • 황준현 (LG전자 디지털 어플라이언스 사업본부 연구소) ;
  • 신종민 (LG전자 디지털 어플라이언스 사업본부 연구소)
  • 발행 : 2002.10.01

초록

The effects of different surfaces on dry and wet frosting test were experimentally investigated. The results of experiment were compared by the performance evaluation coefficient (PEC). Results showed that the air-side pressure drop of lacquer coated evaporator increased by 5% as compared to the plasma treated one. It was also found that the Plasma coated evaporator is lower than lacquer coated one in the PEC ratio.

키워드

참고문헌

  1. Digital Chosunilbo. Lee, M. K.
  2. Refrigerating Engineering v.65 no.2 How frost formation on coils affects refirigeration systems Stoecker, W. F.
  3. Bulletin of JSME v.29 no.251 A studu of extended surface heat exchanger with frosting Aoki, K.;Hattori, M.;Itoh, T.
  4. Proceedings of the 9th International Symposium on Flow Visualization no.413 A study of water hold-up of two surfaces having different hydro-characteristics Shin, J. M.;Kim, J. B.;Kim, C. H.;Ha, S. C.
  5. Proceedings of the SAREK v.10 no.6 The effect of water contact angles of the fin surfaces of the fin-and-tube heat exchangers on the water hod-up Shin, J. M.;Lee, N .G.;Han, S. J.;Ha, S. C.
  6. proceedings of the SAREK (submitted). The study of performances evaluation coefficient fin-and-tube heat exchangers with frosting Choi, B. J.;Hwang, J. H.;Shin, J. M.
  7. Proceedings of the SAREK v.1 The frost and defrost performances of fin-and-tube exchangers with different surface characteristics Choi, B. J.;Shin, J. M.
  8. Proceedings of the SAREK v.1 A study on the frost formation on the surface treated fin-tube heat exchangers Jeong, S. H.;Choi, B. J.;Han, S. J.;Ha, M. Y.