Abstract
The carbon-in-ash system for simultaneously monitoring the unburned carbon in fly ash produced in a coal-fired power plan is designed and evaluated using the domestic fly ash produced in the coal-fired power plant. Real time monitoring is very important to control the combustion of the boiler in the coal-fired power plant and the purification system for fly ash recycling. The carbon-in-ash system based on the capacitance measurement consists of a LCR meter, a duct collector and an electrode cell. The capacitance of fly ash increases linearly with increasing fly ash carbon contents. The water content in fly ash plays an important role on the ash capacitance. The empirical equation for predicting the content of unburned carbon in fly ash produced in the domestic Boryung, Hadong and Samchenpo coal-fired power plants can be derived in the range of carbon content 0-20%.
본 연구는 화력발전소 연소가스 배기덕트 내의 석탄회 미연탄소함량 동시 측정을 위한 석탄회 정전용량 분석에 관한 연구로서, 화력발전소 출력효율 증대, 양질의 석탄회 재활용 및 SOx, NOx등의 유해가스 저감에 기여하고자 하였다. 석탄회 정전용량 측정 시스템은 정전용량 계측기, 입자포집기, 측정셀로 구성되며, 전압이 인가된 양 극판 사이에 석탄회를 투입하여 정전용량을 측정하고 입력주파수, 상대습도, 수분함량, 발전소별 성분비에 따른 정전용량 특성을 분석하였다. 석탄회 정전용량은 미연탄소함량에 따라 비례적으로 증가하였으며, 석탄회 수분함량과 철 함유량이 주된 변수였다. 보령, 하동, 삼천포의 화력발전소별 석탄회의 정전용량특성을 데이터베이스화 하였으며 20% 이하의 미연탄소함량을 예측할 수 있는 경험식을 도출하였다.