By way of driving a 2-way on/off solenoid hydraulic valve with a pulse width modulation (PWM) signal, control of the pressure in a certain volume is frequently used in various applications. However, the pressure built-up according to the duty ratio and carrier frequency of the PWM signal is not so well understood. In order to clarify the characteristics of 2-way valve hydraulic pressure control systems, in this paper two formula fur the mean and ripple of the load pressure were derived through theoretical analysis. And the accuracy of the derived formula were verified by comparison with the experimental test result. Generally 2-way valve systems are constructed as a bleed-off circuit, while 3-way valves are used as a control element in a meter-in circuit pressure control system. In a bleed-off circuit, the system supply pressure from a hydraulic power pack does not remain constant, but changes according to their external load. In turn, the relief valve in the hydraulic power pack reacts accordingly showing complicated dynamic behavior, which makes an analytical study difficult. In order to resolve the problem, simple but accurate empirical dynamic models fer a bleed-off system were used in the course of formula derivation. As the result, selection criteria for two major control parameters of the driving signal is established and the basic strategy to suppress the unnecessary pressure fluctuation can be provided for a hydraulic pressure control system using a 2-way on/off solenoid valve.

Keywords

References

  1. 田中 裕久, 昭和 62年, 油空壓の ディヅタル 制御わ 應用, 近代圓書(株)
  2. Tanaka, H., Araki, K., Ogimura, Y. and Hamamoto, S., 1985, 'Electro-Hydraulic Digital Servo-Mechanism by the Pulse Flow Control,' Proc. Int. Symposium on Fluid Control and Measurement, Tokyo, Japan, pp. 429-434
  3. Tanaka, H., Hiroyoshi, T., 1988, 'Fluid Power 8, Pulse Flow Control Valves and Simplified Proportional Valves,' Proc. 8th Int. Symp. on Fluid Power, BHRA
  4. Jeong Heon-Sul, 1977, 'Pressure Control Characteristics of ON/OFF 3-way Solenoid Valve Driven by PWM Signal,' Transaction of KSME, A, Vol. 21, No.3, pp. 485-501
  5. Jeong Heon-Sul, Park Seong-Jin and Kim Chang-wan, 1997, 'Experimental Comparative Study of PWM Pressure Control Characteristics of 2-Way Solenoid Valve,' Spring conference of KSPE pp. 107-111
  6. Jeong Heon-Sul, Lee Kwnag-Heon and Kim Hyoung-Eui, 'Reexamination of Derivation of Empirical Dynamic Model for a Hydraulic Bleed-Off Circuit,' Transaction of KSME, to be published
  7. Piche, R., Ellman, A., Vilenius, M., 1994, 'Integration of Numerically Stiff Fluid Power Circuit Models Using an L-stable Runge-Kutta Method,' 7th Bath International Fluid Power Workshop, University of Bath
  8. R. M. Corless, G. H. Gonnet, D. E. G. Hare, D. J. Jeffrey, and D. E. Knuth, 1996, 'On the Lambert W function,' Advances in Computational Mathematics, Vol. 5, pp. 329-359 https://doi.org/10.1007/BF02124750
  9. Jeong Heon-Sul, Kim Hyoung-Eui, 'Experimental Based Analysis of the Pressure Control Characteristics of a Oil Hydraulic 3-Way On/Off Solenoid Valve Controlled by PWM Signal,' ASME Journal of Dynamic Systems, Measurements, and Control, Vol. 124, No.1, pp. 196-205
  10. Chang Hyo-Whan, Ahn Byeong-Hong and Lee ChoonHo, 1987, 'A Study on Discontinuous Control Methods for a Hydraulic Position-Control System,' Transaction of KSME, A, Vol. 11, No. 3, pp. 465-72