DOI QR코드

DOI QR Code

배관실험을 통한 국부감육 배관의 손상거동 평가

An Evaluation of Failure Behavior of Pipe with Local Wall Thinning by Pipe Experiment

  • 김진원 (조선대학교 원자력공학과) ;
  • 박치용 (한전 전력연구원 원자력연구실)
  • Kim, Jin-Won (Dept.of Nuclear Engineering, Chosun University) ;
  • Park, Chi-Yong (Atomic Energy Research Center, Korea Electric Power Research Institute)
  • 발행 : 2002.04.01

초록

To understand failure behavior of pipe thinned by flow accelerated corrosion, in this study, the pipe failure tests were performed on 102mm-Sch.80 carbon steel pipe with various local wall thinning shapes, and the failure mode, load carrying capacity, and deformability were investigated. The tests were conducted under loading conditions of 4-points bending and internal pressure. The experimental results showed that the failure mode of thinned pipe depended on magnitude of internal pressure and thinning length as well as loading direction and thinning depth and angle. The variation in load carrying capacity and deformability of thinned pipe with thinning length was determined by stress type appled to the thinning area and circumferential thinning angle. Also, the effect of internal pressure on failure behavior was dependent on failure mode of thinned pipe, and it promoted crack occurrence and mitigated local buckling at thinned area.

키워드

참고문헌

  1. 허남수, 임창주, 김영진, 표창률, 박치용, 2000, '원자력발전소 주요기기의 건전성 평가를 위한 3차원 탄소성 해석 시스템의 개발,' 대한기계학회논문집 A권, 제24권, 제8호, pp. 2015-2021
  2. Choi, Y. H. and Kang, S. C., 2000, 'Evaluation of Piping Integrity in Thinned Main Feedwater Pipes,' J. of Kor. Nucl. Soc., Vol. 32, No. 1, pp. 67-76
  3. Frank, M., Hans, R., and Helmut, S., 2001, 'Experience with piping in German NPPs with Respect to Ageing-Related Aspects,' Nucl. Eng. & Des., Vol. 207, pp. 307-316 https://doi.org/10.1016/S0029-5493(01)00339-9
  4. Chexal, B., Horowitz, J., Dooley, B., Millett, P., Wood, C., and Jones, R., 1998, 'Flow-Accelerated Corrosion in Power Plant,' EPRI/TR-106611-R2
  5. Virginia Electric and Power Co., 1989, 'Surry Unit 2 Reactor Trip and Feedwater Pipe Failure Report.'
  6. Kuen, T. and Yin, P.M., 1999, 'The Evaluation of Erosion/Corrosion Problems of Carbon Steel Piping in Taiwan PWR Nuclear Power Plant.,' Nucl. Eng. & Des., Vol. 191, pp. 231-243 https://doi.org/10.1016/S0029-5493(99)00145-4
  7. Japan Atomic Energy Research Institute, 1993, 'Technical Reprt on the Piping Reliability Tests at the Japan Atomic Energy Research Institute(Japanese),' JAERI-M, 93-074, pp. 104-115
  8. Merz, K. L. and Ibanez, P., 1993, 'Seismic and Dynamic Reliability of Eroded/Corroded Piping Components.,' EPRI TR-102066
  9. American Society of Mechanical Engineer, ASME B&PV Code Sec.III, 1995 ed., 'Nuclear Components.'
  10. American Society of Mechanical Engineer, ANSI/ASME B31.1, 1995ed., 'Power Piping Code.'
  11. American Society of Mechanical Engineer, ASME B&PV Sec.XI, Div. 1, 1998ed., ASME Code Case N-597, 'Requirement for Analytical Evalutaion of Pipe Wall Thinning.'
  12. Wilkowski, G., Stephens, D.,Krishnaswamy, P., Leis, B., and Rudland, D., 2000, 'Progress in Development of Acceptance Criteria for Local Thinned Areas in Pipe and Piping Components,' Nucl. Eng. & Des., Vol. 195, pp. 149-169 https://doi.org/10.1016/S0029-5493(99)00245-9
  13. 최재붕, 김진수, 구본걸, 김영진, 최영환, 2001, '재료물성을 고려한 감육배관의 공학적 한계하중해 제시,' 대한기계학회 춘계학술대회 논문집 A권, pp. 351-356
  14. Ando, K., Ahn, S. H., Ishiwata, M., and Hasegawa, K., 1999, 'Plastic Collapse Behavior of Pipe with Local Wall Thinning Subjected to Bending Moment,' Proc. SMiRT-15, Vol. 5, pp. v257-v264
  15. Miyazaki, K., Kanno, S., Ishiwata, M., Hasegawa, K., Ahn, S. H., and Ando, K., 1999, 'Fracture Behavior of Carbon Steel Pipe with Local Wall Thinning Subjected to Bending Load,' Nucl. Eng. & Des, Vol. 191, pp. 195-204 https://doi.org/10.1016/S0029-5493(99)00141-7