Abstract
Interferometric metrology with a null CGH(computer-generated hologram) is presented for measuring highly aspheric surfaces used in a large screen projection television system with high accuracy. The cubic spline surface model which works in a single-pass configuration with a refractive index of object space 0 is used for designing a null CGH. A hybrid null corrector with plano-concave lens in front of a CGH is presented to make the CGH easier to fabricate. Experimental results are presented to demonstrate the validity of the proposed technique.