Abstract
This study presents a solution to control a Permanent Magnet Synchronous Motor without sensors based on the superposition principle. Because the proposed method of sensorless theory is very simple to compute the estimated angle, computing time to estimate the angle is shorter than other sensorless method. The use of this system yields enhanced operations, fewer system components, lower system cost, energy efficient control system design and increased efficiency. The performance of a sensorless architecture allows an intelligent approach to reduce the complete system costs of the digital motion control applications using cheaper electrical motors without sensors. This paper deals with an overview of sensorless solutions in PMSM control applications whereby the focus will be on the new controller without sensors and its applications.