Abstract
Modern structrues are being built using high-strength and light-weight construction materials resulting in decreased structural mass and damping properties. Rhythmic activities such as jumping, dancing and clapping during lively concerts can produce excessive vibration of steel structures. In this study, dynamic load factors that occur during lively concerts were presented through vibration test and real-time monitoring of an existing concert hall. The vibration test included modal analysis and jumping test according to the forcing frequencies and the number of participants. Dynamic load foactors were acquired directly from peak acceleration responses of each harmonics. Comparing NBCC 1995, the 3rd harmonic must be included in the design of concert halls. Dynamic load factors must be increased as a result of the vibration test.
현대 구조물의 고강도화, 경량화에 따라 구조물의 질량과 감쇠가 줄어들고 있어, 구조물의 진동사용성 문제가 중요하게 부각되고 있다. 특히 율동진동은 공연장, 경기장, 댄스홀, 에어로빅 등과 같이 다수이 군중의 리듬에 맞춰 가진행위가 이루어지는 것으로서, 국내에서도 율동진동에 의한 구조물의 진동문제가 다수 보고되고 있으나 설계기준 미비로 설계단계에서의 대응이 이루어지지 못하고 있다. 그러므로 본 연구에서는 다수의 점핑행위가 예상되는 공연장의 진동설계를 위하여 실제 공연장을 대상으로 진동실험 및 계측을 통하여 동하중계수를 구해냈다. 진동 실험은 실험모드해석과 더불어, 가진진동수별, 율동참여자의 숫자에 따라 실시하였으며, 진동계측은 상시계측시스템을 설치하여 실제 공연시 가속도 응답을 계측하고 동하중계수를 구해내었다. 기존의 NBCC 규준에서는 공연시 2차 조화항까지 고려토록 되어 있으나 연구결과 3차 조화항까지 고려해야 되며, 동하중계수 역시 과소평가 되어 있는 것으로 나타났다.