DOI QR코드

DOI QR Code

Adsorption of Specific Organics in Water on GAC and Regeneration of GAC by Countercurrent Oxidative Reaction


Abstract

Granular activated carbon(GAC) is highly effective in removing organic compounds which are resistant to biological disintegration in wastewater treatment. However, GAC has reached its full adsorptive capacity, GAC needs to be regenerated before it can be used for a further adsorption cycle. Countercurrent oxidative reaction (COR) technique has been developed and evaluated for the regeneration of spent GAC. Various parameters such as flame temperature, the loss of carbon, destruction and removal efficiency (DRE) of organic compounds, surface area, surface structure, adsorptive capacity, etc. were examined to determine the performance of COR. The results of these tests showed that adosorptive capacity of regenerated GAC was completely recovered, the loss of carbon was controllable, flame temperature was high enough to insure complete destruction and removal $(\geq99.9999%)$ of specific organics of interest, polychlorinated biphenyls (PCBs), that are thermally stable, and on formation of toxic byproducts such as polychlorinated dibenzo-p-dioxins (PCDDs) or polychlorinated dibenzofurans (PCDFs) were detected during the regeneration process. The COR technique is environmentally benign, easy to use and less copital intensive than other available regeneration technologies.

Keywords

References

  1. Abu Zeid, N.; Nakhla, G.; Farooq, S.; Osei-Twum, E. Water Research 1985, 29, 653. https://doi.org/10.1016/0043-1354(94)00158-4
  2. Urano, K.; Yamamoto, E.; Tonegawa, M.; Fujie, K. Water Research 1991, 25, 1459. https://doi.org/10.1016/0043-1354(91)90175-P
  3. Streat, M; Patrick, J. W.; Camporro Perez, M. J. Water Research 1995, 29, 467. https://doi.org/10.1016/0043-1354(94)00187-C
  4. McDougall, G. J. J. S. Afr Inst. Min. Metall. 1991, 91, 110.
  5. Tambo, N. In Chemical Water and Water Treatment; Springer, Berlin Heidelberg: U.S.A., 1990; p 17.
  6. Glaze, W. PL; Lay, Y. S.; Kang, J. W. Ind. Eng. Chem. Res. 1995, 34(7), 2314. https://doi.org/10.1021/ie00046a013
  7. Wigmans, T. Carbon 1989, 27, 13. https://doi.org/10.1016/0008-6223(89)90152-8
  8. Cannon, F. S.; Snoeyink, V. L.; Lee, R. G.; Dagois, G. J. Am. Water Works Assoc. 1997, 89,111.
  9. Moreno-Castilla, C; Rivera-utrilla, J.; Jolly, J. P.; Lopez-Ramon, M. V.; Ferrero-Garcia, M. A. Carrascosa-Martin, F. Carbon 1995, 33, 1417. https://doi.org/10.1016/0008-6223(95)00090-Z
  10. Larsen, D. W.; Manahan, S. E. Process for Treatment of Hazardous Wastes by Reverse Burn Gasification; U. S. A.: Patent 4,978,477, 1990.
  11. Ryoo, K. S.; Kim, T. D.; Kim, Y H. Bull. Korean Chem. Soc. 1999, 20, 1447.
  12. Erickson, M. D. Analytical Chemistry of PCBs, 2nd ed.; Lewis/ CRC: Boca Raton, Fla., U.S.A., 1997.
  13. Buser, PL; Bosshardt, H. P. Chemosphere 1978,1, 109.
  14. Buser, PL; Rappe, C. Chemosphere 1979, 3, 157.
  15. Buser, H. Chemosphere 1979, 6, 415.
  16. Tsuji, M; Nakano, T.; Okuno, T. Chemosphere 1987,16, 1889. https://doi.org/10.1016/0045-6535(87)90183-4

Cited by

  1. Adsorption Modeling of Polychlorinated Biphenyls on Fluorisil vol.554, pp.1, 2012, https://doi.org/10.1080/15421406.2012.633859
  2. Improvement of thermal regeneration of spent granular activated carbon using air agent : Application of sintering and deoxygenation vol.31, pp.9, 2014, https://doi.org/10.1007/s11814-014-0125-0