The Effect of Repetitive Insertion and Pullout of Spinal Screws on Pullout Resistance : A Biomechanical Study

척추 수술에 사용되는 나사못의 반복 삽입과 인출이 인장항력에 미치는 영향 : 생체 역학적 연구

  • Bak, Koang Hum (Department of Neurosurgery, School of Medicine, Hanyang University) ;
  • Ferrara, Lisa (Department of Neurological Surgery, The Cleveland Clinic Foundation) ;
  • Kim, Kwang Jin (Department of Mechanical Engineering, University of New Mexico) ;
  • Kim, Jae Min (Department of Neurosurgery, School of Medicine, Hanyang University) ;
  • Kim, Choong Hyun (Department of Neurosurgery, School of Medicine, Hanyang University) ;
  • Benzel, Edward C. (Department of Neurological Surgery, The Cleveland Clinic Foundation)
  • 백광흠 (한양대학교 의과대학 신경외과학교실) ;
  • ;
  • 김광진 ;
  • 김재민 (한양대학교 의과대학 신경외과학교실) ;
  • 김충현 (한양대학교 의과대학 신경외과학교실) ;
  • Received : 2000.05.29
  • Accepted : 2000.08.29
  • Published : 2001.02.28

Abstract

Object : The clinical uses of screws are increasing with broader applications in spinal disorders. When screws are inserted repeatedly to achieve optimal position, tips of screw pitch may become damaged during insertion even though there are significant differences in the moduli of elasticity between bone and titanium. The effect of repeated screw insertion on pullout resistance was investigated. Methods : Three different titanium screws(cortical lateral mass screw, cancellous lateral mass screw and cervical vertebral body screw) were inserted into the synthetic cancellous material and then extracted axially at a rate of 2.4mm/min using Instron(Model TT-D, Canton, MA). Each set of screws was inserted and pulled out three times. There were six screws in each group. The insertional torque was measured with a torque wrench during insertion. Pullout strength was recorded with a digital oscilloscope. Results : The mean pullout force measurements for the cortical lateral mass screws($185.66N{\pm}42.60$, $167.10N{\pm}27.01$ and $162.52 N{\pm}23.83$ for first, second and third pullout respectively : p=0.03) and the cervical vertebral body screws($386.0N{\pm}24.1$, $360.2N{\pm}17.5$ and $330.9N{\pm}16.7$ : p=0.0024) showed consecutive decrease in pullout resistance after each pullout, whereas the cancellous lateral mass screws did not($194.00N{\pm}36.47$, $219.24N{\pm}26.58$ and 199.49N(36.63 : p=0.24). The SEM after insertion and pullout three times showed a blunting in the tip of the screw pitch and a smearing of the screw surface. Conclusions : Repetitive screw insertion and pullout resulted in the decrease of pullout resistance in certain screws possibly caused by blunting the screw tip. This means screw tips suffer deformations during either repeated insertion or pullout. Thus, the screws that have been inserted should not be used for the final construct.

목적 : 최근 척추 수술에 나사못을 사용하는 빈도와 범위가 넓어 지고 있는데 때로 수술 중 한번 삽입하였던 나사못을 다시 사용하는 경우가 있다. 인체 골과 타이타늄의 탄성계수가 크게 차이 나지만 반복 삽입 과정에서 나사못의 이가 손상될 가능성이 있다. 저자들은 나사못의 반복 삽입이 나사못의 인출 저항에 미치는 영향을 조사하였다. 방법 : 각각 6개의 세가지 다른 종류 cortical lateral mass screw, cancellous lateral mass screw and cervical vertebral body screw의 나사못을 시험하였다. 나사못을 인체의 골과 비슷한 밀도의 인공합성골에 삽입하였으며 삽입 중 삽입력을 측정하였고 그 후 Instron(Model TT-D, Canton, MA)을 이용하여 2.4mm의 속도로 인출하여 인장항력을 digital oscilloscope에 기록하였다. 위의 과정을 3회 반복하여 기록한 뒤 나사못을 광학 현미경으로 확대하여 관찰하였다. 결과 : cortical lateral mass screws의 평균 인장항력(1회인장 시험 $185.66N{\pm}42.60$, 2회 인장시험 $167.10N{\pm}27.01$, 3회인장 시험 $162.52N{\pm}23.83$ : p=0.03)과 cervical vertebral body screws ($386.0N{\pm}24.1$, $360.2N{\pm}17.5$ and $330.9N{\pm}16.7$ : p=0.0024)은 반복하여 삽입, 인장 검사 할 때 마다 감소하였으나 cancellous lateral mass screws의 평균 인장항력($194.00N{\pm}36.47$, $219.24N{\pm}26.58$ and $199.49N{\pm}36.63$ : p=0.24)은 감소하지 않았다. 전자현미경 소견에서 나사이의 끝이 무디어지고 표면이 문드러진 것을 관찰할 수 있었다. 결론 : 일부 나사못을 반복하여 삽입한 후 나사못의 인장항력이 감소되었으므로 수술중 여러번 삽입하였던 나사못은 최종 구조물에 사용되지 않아야 한다.

Keywords