Abstract
In determining properties of ductile cast iron, it is well known that nodularity plays a significant role. Therefore, the national and/or international standards for ductile cast iron such as KS, ISO, ASTM and JIS have specified some methods for evaluating it. However, most of standards have not recommended the methods using image analyzer which is known as an objective analyzing tool for evaluating microstructure. In this study, a reliable method for evaluating nodularity by image analyzing method was proposed, and the result was compared with that from the common counting method proposed in KS D 4302-1999. It was found that there was a reasonable relationship in nodularities measured by these two methods.