Air-tightness Test by Silicagel on Museum Cases

조습제(燥濕濟)(Art-Sorb)를 이용한 벽부형진열장(壁附形陳列欌) 밀폐도(密閉度) 간접측정(間接測淀)

  • Yu, Hei-sun (Conservation Science Lab., The National Museum of Korea) ;
  • Kim, Myoung-nam (Conservation Science Lab., The National Museum of Korea) ;
  • Lee, Sung-eun (Conservation Science Lab., The National Museum of Korea)
  • 유혜선 (국립중앙박물관 보존과학실) ;
  • 김명남 (국립중앙박물관 보존과학실) ;
  • 이승은 (국립중앙박물관 보존과학실)
  • Published : 2001.12.01

Abstract

The airtightness of museum cases in museums was measured by using CO2 tracing gas, but it has been pointed that it has a problem with measuring the airtightness of a museum case which has a hole inside before it is used or while is being used. So studies tried to come up with alternatives which make it possible to measure the airtightness of a museum case before it is used or while it is being used if necessary by indirectly measuring the airtightness of the museum case without changing its form. Indirect measuring is done by measuring the change of Art-sorb weight and the change of temperature and humidity inside the museum case. Experiments were made for 12 days with three builtin wall case installed at the same place without turning on the lights but with Art-sorb and the data logger of temperature and humidity put into museum case. The change rate was produced with the change of temperature and humidity inside the museum case divided by that of those around museum case. As a result, the temperature change rate of museum case A(0.67) was lower than that of museum case B(0.69) or museum case C(0.79). The humidity change rate of museum case A(0.12) was lower than that of museum case B(0.19) or museum case C(0.72) showing that its airtightness was the best. Also in the direct airtightness measurement by CO2 tracing gas, the air exchange rate was compared with the humidity change rate by Art-sorb in the indirect measurement.

박물관 진열장의 기밀성은 일반적으로 CO2 추적가스를 이용한 밀폐도를 측정함으로서 조사되어 왔지만 진열장 내부에 구멍을 내야하는 점은 사용전이나 사용 중인 진열장에 대한 밀폐도 측정에 적용하는데 문제점으로 지적되어 왔다. 이에 진열장의 형상을 변화시키지 않고, 진열장의 밀폐도를 간접측정함으로서 사용전이나 필요에 따라서는 전시중인 진열장에 대한 밀폐도를 측정할 수 있는 대안을 제시하고자 하였다. 밀폐도는 간접측정법은 진열장 내부의 온습도변화와 습도조절제(Art-sorb)의 중량변화를 통해 진열장의 기밀도를 간접적으로 알아보는 방법이다. 실험은 동일장소에 시공된 3개의 벽부형진열장을 대상으로 진열장내 조명을 켜지 않고 Art-sorb와 온습도 수집기를 넣고 12일간 진행하였다. 각 진열장내 온도와 습도 변동분을 주변변동분으로 나눠 변동율로 나타냈으며, 그 결과 온도 변동율에서는 벽부장A(0.67)가 벽부장B(0.69)나 벽부장C(0.79)보다 변동율이 적었으며 습도 변동율에서도 벽부장A(0.12)가 벽부장B(0.19)나 벽부장C(0.72)보다 변동율이 적어 기밀도가 가장 양호함을 알 수 있었다. 또한 CO2추적가스를 이용한 직접 밀폐도 측정에서의 공기교환율에 대하여 간접 밀폐도 측정에서의 습도변동율을 대입해 보았다.

Keywords