NOx Removal Characteristics by the Dielectric Packed-bed Plasma Reactor

Dielectric packed-bed 플라스마 반응기를 사용한 NOx 제거 특성에 관한 연구

  • 김응복 (인천대학교 전기공학과) ;
  • 김동욱 (한국전기안전공사 부설 전기안전시험연구원) ;
  • 정영식 (인천대학교 전기공학과) ;
  • 최충석 (한국전기안전공사 부설 전기안전시험연구원) ;
  • 김용하 (인천대학교 전기공학과)
  • Published : 2001.09.01

Abstract

The removal characteristics of nitrogen oxides (NOx) by the dielectric ($Al_2O_3$) packed-bed plasma reactor are experimentally investigated Reactor is packed with 5[mm] diameter $Al_2O_3$ beads, and was desisted to remove NOx at atmospheric pressures from the moving pollution source such as diesel automobile. The experiments were conducted for applied voltages from 5 to 10[kV], flue gas rate from 2 to 5[l/min] and frequency from 0.5 to 2[kHz]. The NOx removal efficiency significantly increasing with increasing applied voltage. Especially removal rate significantly increased with increasing frequency. However, in this experiment discharged poler n relatively high.

Keywords