EFFECT OF LIGHT IRRADIATION MODES ON THE MARGINAL LEAKAGE OF COMPOSITE RESIN RESTORATION

광조사 방식이 복합레진 수복물의 변연누출에 미치는 영향

  • 박은숙 (경북대학교 치과대학 치과보존학교실) ;
  • 김기옥 (경북대학교 치과대학 치과보존학교실) ;
  • 김성교 (경북대학교 치과대학 치과보존학교실)
  • Published : 2001.07.01

Abstract

The aim of this study was to investigate the influence of four different light curing modes on the marginal leakage of Class V composite resin restoration. Eighty extracted human premolars were used. Wedge-shaped class Y cavities were prepared on the buccal surface of the tooth with high-speed diamond bur without bevel. The cavities were positioned half of the cavity above and half beyond the cemento-enamel junction. The depth, height, and width of the cavity were 2 mm, 3 mm and 2 mm respectively. The specimens were divided into 4 groups of 20 teeth each. All the specimen cavities were treated with Prime & Bond$^{R}$ NT dental adhesive system (Dentsply DeTrey GmbH, Germany) according to the manufacturer's instructions and cured for 10 seconds except group VI which were cured for 3 seconds. All the cavities were restored with resin composite Spectrum$^{TM}$ TPH A2 (Dentsply DeTrey GmbH, Germany) in a bulk. Resin composites were light-cured under 4 different modes. A regular intensity group (600 mW/${cm}^2$, group I) was irradiated for 30 s, a low intensity group (300 mW/${cm}^2$, group II) for 60 s and a ultra-high intensity group (1930 mW/${cm}^2$, group IV) for 3 s. A pulse-delay group (group III) was irradiated with 400 mW/${cm}^2$ for 2 s followed by 800 mW/${cm}^2$ for 10 s after 5 minutes delay. The Spectrum$^{TM}$ 800 (Dentsply DeTrey GmbH, Germany) light-curing units were used for groups I, II and III and Apollo 95E (DMD, U.S.A.) was used for group IV. The composite resin specimens were finished and polished immediately after light curing except group III which were finished and polished during delaying time. Specimens were stored in a physiologic saline solution at 37$^{\circ}C$ for 24 hours. After thermocycling (500$\times$, 5-55$^{\circ}C$), all teeth were covered with nail varnish up to 0.5 mm from the margins of the restorations, immersed in 37$^{\circ}C$, 2% methylene blue solution for 24 hours, and rinsed with tap water for 24 hours. After embedding in clear resin, the specimens were sectioned with a water-cooled diamond saw (Isomet$^{TM}$, Buehler Co., Lake Bluff, IL, U.S.A.) along the longitudinal axis of the tooth so as to pass the center of the restorations. The cut surfaces were examined under a stereomicroscope (SZ-PT Olympus, Japan) at ${\times}$25 magnification, and the images were captured with a CCD camera (GP-KR222, Panasonic, Japan) and stored in a computer with Studio Grabber program. Dye penetration depth at the restoration/dentin and the restoration/enamel interfaces was measured as a rate of the entire depth of the restoration using a software (Scion image, Scion Corp., U.S.A.) The data were analysed statistically using One-way ANOVA and Tukey's method. The results were as follows : 1. Pulse-Delay group did not show any significant difference in dye penetration rate from other groups at enamel and dentin margins (p>0.05) 2. At dentin margin, ultra-high intensity group showed significantly higher dye penetration rate than both regular intensity group and low intensity group (p<0.05). 3. At enamel margin, there were no statistically significant difference among four groups (p>0.05). 4. Dentin margin showed significantly higher dye penetration rate than enamel margin in all groups (p<0.05).

저광도 중합법, 펄스 지연 중합법, 초고광도 중합법 등의 광조사 방식이 광중합형 복합레진 수복물에서의 중합수축 응력에 미치는 영향을 알아보기 위해 in vitro에서 미세 누출 실험을 하였다. 80개의 발거된 소구치의 협측면에 5급 와동을 형성하고, 600mW/$cm^2$로 30초간 광조사하는 보통 광도 중합군, 300mW/$cm^2$로 60초간 광조사하는 저광도 중합군, 400mW/$cm^2$로 2초간 광조사하고 5분간 기다린 후 800mW/$cm^2$로 10초간 최종 중합시키는 펄스-지연 중합군, 그리고 1930mW/$cm^2$의 광도로 3초간 광조사하는 초고광도 중합군 등의 4개의 군으로 나누어 hybrid 형의 광중합복합레진을 충전하고 각 군의 방법대로 중합한 후, 변연의 0.5mm 외부에 nail varnish를 도포하고 37$^{\circ}C$, 2% metylene blue 용액에 24시간 동안 침적시켰다. 시편을 아크릴릭 레진에 매몰한 후 수복물의 중앙에서 종절단하여 입체현미경하에서 그 단면을 관찰한 후 법랑질과 상아질 변연으로 나누어 색소의 침투도를 측정하여 다음과 같은 결과를 얻었다. 1. 펄스 지연 중합군의 색소 침투도는 법랑질과 상아질 변연 모두에서 보통광도, 저광도 및 초고광도 중합군과 유의한 차이를 보이지 않았다(p>0.05). 2. 상아질 변연에서 초고광도 중합군은 보통광도 중합군과 저광도 중합군에 비해 유의하게 높은 색소 침투도를 보였다(p<0.05). 3. 법랑질 변연에서의 4개 군의 색소 침투도는 서로 유의한 차이를 보이지 않았다(p>0.05). 4. 모든 군에서 상아질 변연에서의 색소 침투도는 법랑질군에서의 색소 침투도에 비해 유의하게 높았다(p<0.05).

Keywords