Abstract
The operation properties of DBD plasma reactors were observed by using 20 kV square pulse at the cylindrical and planar type of reactors in the condition of air pressure. The optimum operation frequency $f_0$ which optimizes the efficiency of operation was found as such $f_0\proptoexp(-C)$ when the current-voltage curve and charge-voltage curve were observed. Using these properties the dissipated power was evaluated. The dissipated power at the optimum frequency of operation was varied as the value of capacitance which is dependent on the structure and the dielectric material of the reactor, and had the maximum value at the specific value of capacitance. With these value of capacitance, DBD reactors which has a high level of efficiency can be formed.
논문에서는 원통형 및 평판형 반응기에 20 kV의 사각파형 펄스전원을 인가하여 대기압 절연막 방전 플라즈마 반응기의 동작특성을 관찰하였다. 전류-전압파형과 하전량-전압곡선을 관찰한 결과 반응기의 정전용량 크기에 따라서 최적의 운전효율을 갖는 최적운전주파수 $f_0$가 $f_0\proptoexp(-C)$의 관계를 갖고 있음을 알았다. 이 관계를 이용하여 반응기에서 소실되는 소모전력을 구하였다. 반응기의 소모전력은 반응기의 구조와 전극의 유전물질의 종류 등의 함수인 반응기 정전용량 값에 따라서 변화하였으며 반응기의 특정한 정전용량 값에서 최대값을 가졌다. 이 정전용량 값을 이용하여 최적효율을 갖는 DBD 반응기를 설계할 수 있을 것으로 사료된다.