Abstract
In this study, ground reaction force(GRF) and energy consumption of fixed. single-axis and multi-axis Prosthetic ankle assemblies were investigated to show the biomechanical evaluation for trans-tibial amputees. In the experiments. two male and two female trans-tibial amputees were tested with fixed, sin91e-axis and multi-axis Prosthetic ankle assembly. A three-dimensional gait analysis was carried out to derive the ratio of GRF to weight as the percentage of total stance Phase for nine Points Energy consumption of each Prosthetic ankle assembly was measured while subjects walked at 2km/h. 3km/h and the most comfortable walking speed on the treadmill The results showed that multi-axis ankle was superior to the other two ankle assemblies for the characteristic of forwarding and breaking forces. Fixed ankle was relatively superior to the other two ankle assemblies for gait balancing and movement of the center fur mass Compared to the other ankle assembly. sing1e-axis type showed lower energy consumption over 2.3km/h walking speed .
본 연구에서는 하퇴 절단환자에서 고정형. 단축형, 다축형 인공족관절 장착시 지면반발력과 에너지 소비량을 측정하여 하퇴의지에 대한 생체역학적 평가를 하였다. 실험에는 각각 2명의 남성과 여성 하퇴 절단 환자가 3종류의 의지를 착용하고 참여하였으며. 3차원 보행분석은 7개의 기준점에 대하여 전체 입각기에 대한 지면 반발력의 체중에 대한 비율로 나타내었다. 하퇴의지 에너지 소비량은 피 실험자들이 각각 2km/h, 3km/h 그리고 가장 걷기 편한 속도로 런닝머신 위에서 보행하게 하면서 측정하였다 실험결과는 지면반발력에서 다축형 인공족관절 장착시 추진력과 후진력의 보행특성에 대하여 우위를 보이며, 고정형 인공족관절 장착시에는 보행균형과 무게중심의 이동에 대해 상대적인 우위를 보였다. 에너지 소비량은 2.3km/h 이상의 보행속도에서 단축형 인공족관절 장착시 다른 두 의지에 비해 적은량의 에너지 소비를 보였다.