The Development of a High Efficiency Luminaires Reflector for Tunnel Lighting

터널용 고효율 조명기구 반사판의 개발

  • 김기훈 (강원대 공대 전기공학과 대학원) ;
  • 황재산 (강원대 공대 전기공학과 대학원) ;
  • 윤미림 (강원대 공대 전기공학과 대학원) ;
  • 김훈 (강원대 공대 전기전자정보통신공학부)
  • Published : 2001.03.01

Abstract

Tunnel lighting in Korea has the problems of unsatisfactory illuminance uniformity which obstructs driver's vision, a flicker phenomenon on wall of tunnel, a heavy glare, low efficiency of luminaires, low utilization factor, and high energy consumption. We developed a high efficiency luminaire reflector for tunnel lighting which removes these problems. Developed luminaire saves energy and improves lighting environment by increasing 10% of luminaire efficiency. It can reduce installation cost by decreasing the number of luminaires, while average illuminance of 200[lx], overall uniformity of 0.4, longitudinal uniformity of 0.7, and electric power consumptions per unit area of 3.7[W/m$^2$] are accomplished.

우리 나라의 터널 조명은 운전자의 시야상태를 저해하는 불균일한 조도 균제도, 터널 내의 플리커 현상, 심한 눈부심 등과 함께 낮은 기구효율, 낮은 조명률, 높은 에너지 소비 등의 문제점을 갖고 있다. 이러한 것들을 개선 하기 위해서 터널용 고효율 조명기구의 반사판을 개발하였고, 개발된 조명기구는 기구 자체 효율이 10%이상 상승함으로써 에너지의 절감과 조명효과의 상승을 가져왔으며, 기구 대수의 저감으로 시설비를 절감할 수 있다. 또한 이것을 이용한 터널조명에서는 평균조도 200[lx]이상, 전반 균제도 0.4이상, 차선축 균제도 0.7이상, 단위 면적당 소비전력 3.7 [W/m$^2$]이하의 효과를 얻었다.

Keywords

References

  1. 휘도 측정에 의한 터널 조명 실태조사와 개선 방안 강래철
  2. 조명전기설비학회지 v.12 no.1 고속도로 터널조명 시설 지철근;이진우
  3. 도로 터널의 조명 설비에 관한 검토와 개선 방안 정인식
  4. The Optical Design of Reflectors WILLIAM B. ELMER