Experimental Study on the Mean Flow Characteristics of Forward-Curved Centrifugal Fans

  • Published : 2001.12.01

Abstract

Measurements have been made in an automotive HVAC b1ower for two different centrifugal fans. This work is directed at improving the performance of a conventional forward-curved centrifugal fan for a given small blower casing. Mean velocities and pressure have been measured using a miniature five-hole probe and a pressure scanning unit connected to an online data acquisition system. First, we obtained the fan performance versus flow rates showing a significant attenuation of unstable nature achieved with the new fan rotor in the surging operation range. Second, aerodynamic characterizations were carried out by investigating the velocity and pressure fields in the casing flow passage for different fan operating conditions. The measurements stowed that performance coefficients are strongly influenced by flow characteristics at the throat region. The main flow features ware common in both fans, but improved performance is achieved with tole new fan rotor, particularly in lower flow rate legions. Based on the measured results, design improvements were carried out in an acceptable operation range, which gave considerable insight into what features of flow behavior ware most important.

Keywords

References

  1. Bommes, L., Grundmann, R., Klaes, K. and Kramer, C, 1995, 'Effects of Blade Design on Centrifugal Fan Noise and Performance,' Noise Control Engineering Journal, Vol. 43, No.4, pp. 91-101
  2. Cau, G., Mandas, N., Manfrida and Nurzia, F., 1987, 'Measurements of Primary and Secondary Flows III an lndustrial Forward-Curved Centrifugal Fan,' ASME Journal of Fluids Engineering, Vol. 109, pp. 353-358
  3. Eck, B., 1973, 'Fans,' 1st English ed. , Pergamon Press, Oxford
  4. Fehse, K.-R. and Neise, W., 1999, 'Generation Mechanisms of Low-Frequency Centrifugal Fan Noise,' AIAA Journal , Vol. 37 , No. 10, pp. 1173-1179
  5. Kind, R. J. and Tobin, M. G., 1990, 'Flow in a Ccntrifugal Fan of the Squirrel-Cage Type,' ASME Journal of Turbomachinery, Vol. 112, pp. 84-90
  6. Kind, R. J, 1997, 'Prediction of Flow Behavior and Performance of Squirrel-Cage Centrifugal Fans Operating at Medium and High Flow Rmes,' ASME Journal of Fluids Engineering, Vol. 119, pp. 639-646
  7. Koopmann, G. H., Neise, W. and Chen, W., 1988, 'Active Noise Control to Reduce the Blade Tone Noise of Centrifugal Fans,' Journal of Vibration, Acoustics, Stress, and Reliability in Design, Vol. 110, pp. 377-383
  8. Kwon, E. Y., Back, K. W., Cho, N. R., Kim, H., K., and lung, J., J., 2001, 'Some Aerodynamic Aspects of Centrifugal Fan Characteristics of an Automotive RV AC Blower,' SAE Paper 2001-01-0291, Detroit, USA
  9. Morinushi, K., 1987, 'The Intluencc of Geometric Parameters on F. C. Centrifugal Fan Noise,' Journal of Vibration, Acoustics, Stress, and Reliability in Design, Vol. 109, pp. 227-234
  10. Ohta, Y, Outa, E. and Tajima, K., 1996, 'Evaluation and Prediction of Blade-Passing Frcquency Noise Generated by a Centrifugal Blower,' ASME Journal of Turbomachinery, Vol. 118. pp. 597-605
  11. Raj, D. and Swim, W. B., 1981, 'Measurements of the Mean Flow Velocity and Velocity Fluctuations at the Exit of an FC Centrifugal Fan Rotor,' ASME Journal of Engineering for Power, Vol. 103, pp. 393-399
  12. Roth, H. W., 1981, 'Optimierung von Trommellaufer-Ventilatoren,' Stromungsmechanik und Stromungs-Maschinen, Vol. 29, pp. 1-45
  13. Shepherd, I. C. and Lafontaine, R. F., 1992, 'Measurement of Vorticity Noise Sources in a Centrifugal Fan,' Proceedings of the SFA Symposium on Fan Noise, Senlis, France
  14. Velarde-Suarez, S., Santo1aria-Morros, C. and Ballesteros-Tajadura, R., 1999, 'Experimental Study on the Aeroacoustic Behavior of a Forward-Curved Blades Centrifugal Fan,' ASME Journal of Fluids Engineering, Vol. 121, pp. 276-281