Feasibility Study of the Decay Heat Removal Capability Using the Concept of a Thermosyphon in the Liquid Metal Reactor

  • 발행 : 2001.11.01

초록

A new design concept for a decay heat removal system in a liquid metal reactor is proposed. The new design utilizes a thermosyphon to enhance the heat removal capacity and its heat transfer characteristics are analyzed against the current PSDRS (Passive Safety Decay heat Removal System) in the KAL IMER (Korea Advanced LIquid MEtal Reactor) design. The preliminary analysis results show that the new design with a thermosyphon yields substantial increase of 20∼40% in the decay heat removal capacity compared to the current design that do not have the thermosyphon. The new design reduces the temperature rise in the cooling air of the system and helps the surrounding structure in maintaining its mechanical integrity for long term operation at an accident. Also the analysis revealed the characteristics of the interactions among various heat transfer modes in the new design.

키워드

참고문헌

  1. Proc. of the 5th Nuclear Thermal Hydraulics Evaluation of Heat Pipes for Decay Haet Removal Litwin, R.Z.;Delgado, A.
  2. Ann. Nucl. Energy v.17 no.3 On Application of Heat Pipes for Passive Shutdown Heat Removal in Advanced Liquid Metal and Gas-Cooled Reactor Designs Razzaque, M.M.
  3. Nuclear Engineering and Design v.199 Heat Transfer Enhancement by Radiation Structures for An Air Channel of LMR Decay Heat Removal Sim, Y.S.;Kim, S.O.;Wi, M.H.;Kim, E.K.
  4. Heat Pipes(3rd Edition.) Dunn, P.D.;Reay, D.A.
  5. Int. J. Heat Mass Transfer v.15 A Tow-Phase Closed Thermosyphon Lee, Y.;Mital, U.
  6. Int. J. Heat Mass Transfer v.21 The Characteristics of Heat Exchangers Using Heat Pipes or Thermosyphons Lee, Y.;Bedrossian, A.
  7. KNS '98 Spring Conf. The Characteristics of Residual Heat Removal Capability of PSDRS Sim, Y.S.;Wi, M.H.;Kim, S.O.
  8. Code PARS User's Manual, KALIMER/FS500-CM-01/2000 Wi, M.H.
  9. Convection Haet Transfer Bejan Adrian
  10. Proceedings of the 4th Int. Heat Pipe Conf. Heat Pipe Dry Cooling for Electrical Stations Robertson, A.S.;Cady, E.C.