Inelastic Energy Absorption Factor for the Seismic Probabilistic Risk Assessment of NPP Containment Structure

확률론적 지진위험도 분석을 위한 원전 격납건물의 비탄성에너지 흡수계수 평가

  • Published : 2001.10.01

Abstract

In order to assure the safety of NPP structures, margin of safety or conservatism is incorporated in each design step. Seismic risk evaluation of NPP structures is performed based on the realistic capacity and response of structure eliminated the safety margin and conservatism. In this study, the comparative study on the various evaluation methods of the inelastic energy absorption capacity was performed. The inelastic energy absorption capacity due to the nonlinear behavior of structures has significant effect on the results of seismic probabilistic risk assessment. And the comparison study of the HCLPF(high confidence of low probability of failure) values according to the inelastic energy absorption factors was performed. As a conclusion, the inelastic energy absorption factor of NPP containment structure is estimated about 1.5~1.75. It is essential to estimate the nonlinear behavior of structure and its ductility factor correctly for the seismic risk assessment.

원전 격납건물은 내진 안정성을 확보하기 위해 설계단계에서 여유나 보수성을 부여하게 된다. 원전 구조물의 내진성능 평가는 이러한 여유나 보수성을 배제한 실질적인 성능 및 응답을 기준으로 평가하게 된다. 본 연구에서는 내진성능 평가에 고려되는 구조물의 성능 및 응답관련 계수들 중 그 기여도가 비교적 큰 비탄성 에너지 흡수계수의 산정방법에 대한 비교를 수행하였다. 또한 각종 방법에 따라 산정된 비탄성 에너지 흡수계수에 따른 HCLPF(high confidence of low probability of failure)값의 변화를 분석하였다. 연구결과 원전 격납건물의 비탄성 에너지 흡수계수는 1.5~1.75로 나타났다. 구조물의 내진성능을 명확히 평가하기 위해서는 먼저 구조물의 비선형 거동 및 연성도를 정확히 평가하여야 함을 알 수 있다.

Keywords

References

  1. Nuclear Engineering and Design v.79 Seismic fragilities for nuclear power plant risk studies Kennedy, R. P.;Ravindra, M. K.
  2. JAERI-Research 96-059 Methodology for estimating realistic response of buildings and components under earthquake motion and its application Ebisawa, K.(et al.)
  3. SMiRT-4 v.K4 no.1 Inelastic design of nuclear reactor structures and its implications on design of critical equipment Newmark, N. M.
  4. Proc. of the 2nd US Conference on Earthquake Engineering A statistical study of inelastic response spectra Newmark, N. M.;Riddell, R.
  5. NUREG/CR-3805 Engineering characterization of ground motion Kennedy, R. P.;Short, S. A.;Merz, K. L.;Tokarz, F. J.;Idriss, I. M.;Power, M. S.;Sadigh, K.
  6. Report No. 1643.1 Probabilistic evaluation of the diablo canyon turbine building seismic capacity using nonlinear time history analyses, Prepared for Pacific Gas & Electric Company Kennedy, R. P.;Wesley, D. A.;Tong, W. H.
  7. EPRI TR-103959 Methodology for developing seismic fragilities Reed, J. W.;Kennedy, R. P.
  8. Report No. 1643.02 Seismic fragilities of civil structures and equipment components at thd Diablo Canyon power plant, prepared for Pacific Gas & Electric Company Kipp, T. R.;Wesley, D. A.; Nakaki, D. K.
  9. NUREG/CR-0098 Development of criteria for seismic review of selected nuclear power plants Newmark, N. M.;Hall, W. J.
  10. Nuclear Engineering and Design v.192 Seismic capacity evaluation of the prestressed/reinforced concrete containment, Younggwang nuclear power plant units 5 and 6 Lee, N. H.;Song, K. B.
  11. Report No. 9-310-C455-0 Seismic analysis of containment building Korea Electric Power Corporation
  12. EPRI NP-6041-SL A methodology for assessment of nuclear power plant seismic margin(revision 1) Reed, J. W.;Kennedy, R. P.;Buttemer, D. R.;Idriss, I. M.;Moore, D. P.;Barr, T.;Wooten, K. D.;Smith, J. E.
  13. Boiler and pressure Vessel Code ASME
  14. SMiRT-6 v.J4 no.3 Shear strength tests of prestressed concrete containment vessels Ogaki, Y.;Kobayashi, M.;Takeda, T.;Yamaguchi, T.;Yoshizaki, K.;Sugano, S.
  15. SMiRT-6 v.J4 no.2 Horizontal loading test on largescale model of prestressed concrete containment vessel Ogaki, Y.;Kobayashi, M.;Takeda, T.;Yamaguchi, T.;Yoshioka, K.
  16. Proceedings of the OECD/NEA workshop on the Seismic Re-evaluation of All Nuclear Facilities Seismic re-evaluation of existing nuclear power plants:An introduction to an IAEA safety report Labbe, P.
  17. EQE Project Number: 52042.01 Seismic and wind fragility evaluation of Korinuclear power plant unit 4, repared for NUS corporation Ravindra, M. K.;Tong, W. H.;Kipp, T. R.;Bragagnolo, L. J.