Abstract
Rock slope near the road or railroad is affected by the outside temperature and iterative freezing-thawing process during winter and early spring. The purpose of this study is to analyze the stability of rock slope which is iniluenced by deterioration due to the freezing-thawing. Method of analysis is homogenization method which find the strength property of discontinuous rock mass and as a strength failure criterion, Drucker-Prager failure criterion is used, The deterioration property of real rock is obtained by a freezing-thawing labordtory test of tuff and this quantitative property is used as a basic data of stability analysis of rock mass. To evaluate the deterioration depth due to the freezing-thawing in the field rock slope, one dimensional heat conductivity equation is used and as a a result we can find the depth of which is affected by a temperature. After determined the freezing-thawing depth of model slope, the pattern of rock mass strength value of model rock slope which excess the limit of self-load is analyzed.
도로나 철도 변에 나타나는 암반사면은 외부 기온에 영향을 받아 동절기부터 이른봄에 걸쳐 동결융해작용을 반복해서 받는다. 본 연구의 목적은 불연속성 암반이 동결융해작용을 반복하여 받을 경우 열화현상을 겪게 되고 이에 따른 암반의 안정성이 어떻게 변화되는가를 해석한다. 해석방법으로는 균질화법을 이용하여 불연속성 암반의 강도특성을 밝히고 파괴기준으로는 드러커-플래커 기준을 이용한다. 또한 실제 암석의 열화특성은 응회암을 채취하여 실내 동결융해실험에 의하여 열화특성을 정량화 하여 암반의 안정성 해석의 기초 자료로 이용한다. 현장사면에서 동결융해에 의한 열화의 깊이를 추정하기 위하여 일차원 열전도 방정식을 이용하여 온도에 영향을 받는 깊이를 구한다. 모델 사면의 동결융해 깊이를 결정한 후 모델 암반사면에서 암반의 강도 값의 변화양상을 해석한다. 암반의 작용하는 외력은 자중에 의한 중력만이 작용한다고 가정하고 안전율 해석을 실시한다. 그 결과 암반의 안정성 변화양상을 정량적으로 분석한다. 대상으로 하는 두 도시의 경우 동결융해 영향을 받는 깊이는 1.0m 내외 였으며 10년 경과 후에는 암반의 붕괴 조짐을 나타나는 것을 추측할 수 있다.