References
- Cerrolaza, M., Herrera, M., Berrios, R. and Annicchiarico, W., 1997, 'A Comparison of the Hydrodynamical Behaviour of Three Heart Aortic Prostheses by Numerical Methods,' J. Medicine Engineering and Technology(to appear)
- Chandran, J.B., 1985a, 'Pulsatile Flow Past a St. Jude Medical Bileaflet Heart,' J. Thorac. Cardiovasc. Surg., 89, 743-749
- Chandran, K. B., Cabel, G. M, Khalighi. and Chen, C. J., 1985b, 'Laser Anemometer Measurements of Pulsatile Flow Past Aortic Valve Prostheses,' J. Biomechanics, 16(10), 865-873
- Chandran, K.M., Khalighi, B. and Chen, C.J., 1985c, 'Experimental Study of Physiological Pulsatile Flow Past Valve Prosthese in a Model of Human Aorta-II. Tiling Disc Valves and the Effect of Orientation,' J. Biomechanics, 18(10), 773-778 https://doi.org/10.1016/0021-9290(85)90052-1
- Farahifar, D., Cassot, F. and Bedard, H., 1985, 'Velocity Profiles in the Weak of Two Prosthetic Heart Valves Using a New Cardiovascular Simulator,' J. Biomechanics, 18(10),789-802 https://doi.org/10.1016/0021-9290(85)90054-5
- Fatermi, R.S. and Chandran, K.B., 1989, 'An in Vitro Study of the St. Jude Medical and Edwards Durornedics Bileaflet Valve Using Laser Anemornetry,' J. Biomech. Eng., 111, 298-302
- Gokhale, V.V., Tanner, R.J. and Bischoff, K.B., 1978, 'FE solution for the Navier-Stokes equations for a 2D steady flow through a section of a canine aorta model,' J. Biomechanics, 11, 241-249 https://doi.org/10.1016/0021-9290(78)90050-7
- Gross, J.M., Shermer, C.D. and Hwang, N.H.C., 1988, 'Vortex shedding in bileaflet heart valve prostheses,' Trans. Am. Soc. Artif. Intern. Organs, 34, 845-840
- Hasenkam, J.M., Mygaard, H., Giersiepen, M., Reul, H. and Stodkilde-Jorgensen, H., 1988, 'Turbulent Stress Measurements Downstream of Six Mechanical Aortic Valves in a Pulsatile flow Medel,' J. Biomechanics, 21, 631-645 https://doi.org/10.1016/0021-9290(88)90201-1
- Imaeda, K. and Goodman, F., 1980, 'Analysis of Non-linear Pulsatile Flow in Areries,' J. Biomechanics, 13(8), 1007-1002 https://doi.org/10.1016/0021-9290(80)90045-7
- King, M.J., Computational and experimental studies of flow through a bileaflet mechanical heart valve, Ph. D. Thesis. University of Leeds, UK, 1994
- King, M.J., Corden, J., David, T., and Fisher, J., 1996, 'A Three-Dimensional, Time-Dependent Analysis of Flow Through a Bileaflet Mechanical Heart Valve : Comparison of Experimental and Numerical Results,' J. Biomechanics, Vol. 29, No.5, pp. 609-618 https://doi.org/10.1016/0021-9290(95)00107-7
- King, M.J., David, T. and Fisher, 1994, 'An Initial Parametric Study of Fluid Flow Through Bileaflet Mechanical Heart Valves Using Computational Fluid dynamics,' J. Eng. Med., 208, 63-71
- Krafczyk, M., Cerrolaza, M., Schulz, M. and Rank, E., 1998, 'Analysis of 3d Transient Blood Flow Passing Through an Artificial Aortic Valve by Lattice- Boltzmann Methods,' J. biomechanics, Vol. 31, pp. 453-462 https://doi.org/10.1016/S0021-9290(98)00036-0
- McQueen, D. M. and Peskin, C, 1985, 'Computer-Assisted Design of Butterfly Bileaflet Mechanical Heart valves for the Mitral Position,' J. Comput. Fluids, 82, 289-297
- Nygaard, H., Paulsen, P. K., Hasenkan, J. M., Pedersen, E. M. and Rovsing, 1994, 'Turbulent Stresses Down-Stream of Three Mechanical Aortic Valve Prostheses in Human Beings,' J. Thome. Cardiovas. Surg., 107,438-446
- Rossean, E.P. M., Van de Ven AP . C, Van Steenhoven, A.A. and Seroo, J.M., 1984, 'Design of a System for the Accelerated Loading of Heart Valve Prosthese,' J. Biomechanics, 17(2), 145-153 https://doi.org/10.1016/0021-9290(84)90132-5
- Sallam, L.A., Shaw, A. and Bain, W.H., 1976, 'Experimental Evaluation of Mechanical haemolysis with Starr-Edwards, Kay-Shiley and Bjork Shiley Valves,' Scandinavian J. Thoracic and Cardiovascular Surgery, 10, 117-122
- Sikarskic, D.L., Stein, P. and Vable, M., 1979, 'A mathematical for arotic valve vibration.' J. Biomechanics, 17(11), 831-837 https://doi.org/10.1016/0021-9290(84)90141-6
- Skalak, R., Finite elements in biofluid mechanics. FE Anaysis in Biomechanics, 1982
- Stevenson, D.M. and Yoganathan, A.P., 1985, 'Numerical simulation of steady turbulent flow through trileaflet aortic heart valves-? Computational scheme and methodology,' J. Biomechanics, 18(12), 899-907 https://doi.org/10.1016/0021-9290(85)90034-X
- Swanson, W.M. and Clark, R. E., 1974, 'Dimensions and Geometric Relationships of the Human Aortic Valve as a function of Pressure,' Cir. Res., Vol. 35, pp. 871-882
- Thubrikar, M.J., Selim, G, Robicsek, F. and Fowler, B, 1996a, 'Effect of the sinus geometry on the dynamics of bioprosthetic heart valves(abstract),' Ann. Biomed. Eng., 24, S3
- Thubrikar, M.J., Selim, G, Robicsek, F. and Fowler, B, 1996b, 'Effect of the Sinus Geometry on the Dynamics of Bioprosthetic Heart Valves (abstract),' Proceedings of the 18th Annual International Conference of the IEEE Engineering in Medicine and Biology Society Amsterdam, The Netherlands, pg. 10 November https://doi.org/10.1109/IEMBS.1996.652841
- Tillman, W., Reul, H., Herold, M., Bruss, K. H. and Van Gilse, J., 1984, 'In vitro wall shear measurements at aortic valve prostheses,' J. Biomechanics, 17(4),263-279 https://doi.org/10.1016/0021-9290(84)90137-4
- Woo, Y.R. and Yoganathan, A.P., 1986, 'Pulsatile flow velocity and shear stress measurements on the St. Jude valve prosthesis,' Seand. J. Thorac. Cardiovasc. Surg., 20, 15-28
- Yang. H.Q. and Makhijani, V.B. 1994, 'A strongly coupled pressure-based CFD agroithm for fluid-structure interaction,' Proceeding of 32nd Aerospace Sciences meeting and Exhibit, Reno, NV, AIAA-94-0719
- Yoganathan, A.P., Coreoran, W. H. and Harrison, E. C., 1979, 'In Vitro Velocity Measurements in the Vicinity of Aortic Prostheses,' J. Biomechanics 12, 135-152 https://doi.org/10.1016/0021-9290(79)90153-2