Evaluation Method I of the Small Current Breaking Performance for SF(sub)6-Blown High-Voltage Gas Circuit Breakers

초고압 $SF_6$ 가스차단기의 소전류 차단성능 해석기술 I

  • 송기동 (한국전기연구원 신전력기기그룹) ;
  • 이병운 (한국전기연구원 신전력기기그룹) ;
  • 박경엽 (한국전기연구원 신전력기기그룹 그룹장) ;
  • 박정후 (부산대 공대 전자전기통신공학과)
  • Published : 2001.07.01

Abstract

With the increasing reliability of analysis schemes and the dramatically increased calculating speed, the computer simulation has become and indispensable process to predict the interruption capacity of circuit breakers. Generally, circuit breakers have to possess both the small current and large current interruption abilities and the circuit breaker designers need to evaluate its capacities to save the time and the expense. The analysis of small current and the large current interruption performances have been considered separately because the phenomena occurring in a interrupter are quite different. To analyze the dielectric recovery after large current interruption many physical phenomena such as heat transfer, convection and arc radiation, the nozzle ablation, the ionization of high temperature SF(sub)6 gas, the electric and themagnetic forces and so forth mush be considered. However, in the analysis of small current interruption performance only the cold gas flow analysis needs to be carried out because the capacitive current is to small that the influence from the current can be neglected. In this paper, an empirical equation which is obtained from a series of tests to estimate the dielectric recovery strength has been applied to a real circuit breaker. The results of analysis have been compared with the test results and the reliability has been investigated.

Keywords

References

  1. Klaus Ragaller, Current Interruption in High-Voltage Networks, Plenum press, pp269-294, 1978
  2. Allan Greenwood, Electrical Transients in Power Systems, John & Sons, Inc., pp92-122, 1991
  3. F. Endo, M. Sato, et al., 'Analytical Prediction of Transient Breakdown Characteristics of SF6 Gas Circuit Breakers', IEEE Transactions on Power Delivery, 89 WM 075-3, pp1731-1737, 1989
  4. T. Onchi, S. Sugiyama et al., 'An Estimation of Current Breaking Performance of GCBs Using a Gas Flow Analysis', Proceedings of the XIII International Conference on Gas Discharges and Their Applications GD 2000, Vol. 1 pp42-45, Sept. 2000
  5. S. Manganaro, A. Romiti, S. Rovelli,'Recent Experience with Synthetic Circuits for Capacitive Current Switching Tests on HV Circuits Breakers', IEEE/PES 1983 Winter Meeting, 83WM 125-2 pp1-8, 1983
  6. 송기동, 박경엽, 송원표, '초고압 가스차단부내의 냉가스 유동해석', 대한전기학회 논문지 49권 6호, pp387-394, 2000년 6월