Abstract
The noise level of the navigation bridge as well as topside of the superstructure is dominated by the exhaust gas noise of the high-powered main engine and generator engine of special purpose vessels. In the case of the noise radiated from the top of the funnel. the exhaust pipe can be fitted with a silencer to reduce the propagated noise level. This paper is prepared based on an experimental performance test results of the silencers for generator-engine exhaust gas noise with consideration of air velocity. Two silencers were examined to check the performance of noise reduction in cases of air velocity 0m/s and 32m/s. In the sound reduction test, 400mm and 600mm diameter pipe ducts equipped with an axial fan were used as exhaust gas pipe system in the actual ship. The test procedure and results are presented in detail.
선박의 주기관 및 발전기의 실린더내의 폭발소음은 배기관을 통하여 연돌 상부에서 전파되어 인접한 거주구 상층부 및 bridge wing 등의 소음을 증가시키는 주 요인이 되고 있다. 본 연구에서는 실제의 배기관인 400mm 및 600mm의 지름의 관에 대하여 0m/s 및 32m/s의 유속에 대하여 25dB 및 35dB silencer에 대하여 감음 성능을 실험하였다. 관내 유속은 축류 팬에 의하여 발생시켰고 실제 소음기(silencer)를 사용하여 감음 성능을 실측하였다.