The Simulation on Dose Distributions of the 6 MeV Electron Beam in Water Phantom
6 MeV 전자선의 물팬텀 속의 선량분포에 관한 모의계산
- Lee, Jeong-Ok (Department of Radiotechnology, Wonkwang Health Science College) ;
- Jeong, Dong-Hyeok (Department of Radiation Oncology, Wonkwang University, School of Medicine) ;
- Moon, Sun-Rock (Department of Radiation Oncology, Wonkwang University, School of Medicine)
- Published : 2000.12.30
Abstract
This study was performed for the clinical applications applying the Monte Carlo methods. In this study we calculated the absorbed dose distributions for the 6 MeV electron beam in water phantom and compared the results with measured values. The energy data of electron beam used in Monte Carlo calculation is the energy distribution for 6 MeV electron beam which is assumed as a Gaussian form. We calculated percent depth doses and beam profiles for three field sizes of