The Study on the Protection and Actual Condition of Using the Dental X-ray Unit

치과진단용 X선발생장치의 이용 실태 및 방어에 관한 연구

  • Kang, Eun-Ju (Dept. of Dental Hygiene, Wonkwang Health Science college) ;
  • Yoo, Beong-Gyu (Dept. of Radiotechnolgy, Wonkwang Health Science college)
  • Published : 2000.12.30

Abstract

This paper will present the result of research which was done with 201 places on the actual condition of using dental diagnostic radiography unit and the protection of radiography. The purpose of this paper is to comprehend the actual condition of using dental x-ray unit and to protect when they do radiation work. Moreover this paper was completed to prepare basic materials that could be helpful to reduce the exposure from radiation. This paper obtains the following result. 1. On radiation photographing work in the dentist office, 50.3% of dental hygienists treat this job, and 19.2% of assistants, 10.8% of dentists, 5.6% of radiolotechnologists and 4.2% others performed this job. 2. The case that radiation worker is educated about diagnostic radiography safety supervision has been shown 14.4% and uneducated case has been shown 78.1%. 3. The result about the actual condition of using the oral diagnostic radiation per day was that a number of film which take photograph again (less than 1 exposure) was 40.3%. Normal photographing($1{\sim}10$ exposure) was 85.1% which is the highest percentage. Using the bitewing film and occlusal film was 7.0%, and 12.4% respectively. The percent that they use cephalo film and panoramic film was 16.4% 29.8% respectively. 4. Dental intra diagnostic radiography unit made in $1996{\sim}2000$ was 24.9% and the one made in $1991{\sim}1995$ was 19.9%, in $1986{\sim}1990$ was 19.9%, in 1985 was 9.5% according to the answer. On kVp, they use 60 kVp mostly(61.7%) and On mA, they use 10 mA with the highest percent(66.7%). On the dental extra diagnostic radiography units which are used for doing the extra oral radiography, the one made in $1996{\sim}2000$ was 13.4%, in $1991{\sim}1995$ was 9.5%, in $1985{\sim}1990$ was 2.0% according to the answer. They use $71{\sim}80\;kVp$ with 10.9% and $60{\sim}75\;kVP$ with 9.5%. They use less than 10 mA with 19.4% and $11{\sim}15\;mA$ with 2.5%. $16{\sim}20\;mA$ with 1.5%. But the case they exactly do not know how much mA they use or they do not have any mA was 76.6%. 5. General characteristics and the part of protection through the protective equipment by operator are completed with 89.1%. They have shown the similar difference in the relationship with age(p<0.001), experience(p<0.05) and in-patient(p<0.05). 6. When they take photographs of radiation with general quality, how far they keep the proper distance from the cone is as follows, Keeping safe distance is 12.9% according to the answer with the low percent. This result is similar with the difference related in experience(p<0.05) and work(p<0.05), the area of working(p<0.05) and in-patient(p<0.05). 7. The answer about the question-if they hold the tube head when they take photographs with general characteristics is as follows. The answer that they never hold the tube head and cone occupies 62.7% with the highest percent. It is shown the similar difference with age(p<0.05). 8. According to the study that they put on dosimeter with general characteristics is as follows. 64.7% has never put on the dosimester with the highest percent. 33.8% showed similar differences with experience(p<0.05), work(p<0.001), the area of work(p<0.005)and in-patient(p<0.001).

Keywords