DOI QR코드

DOI QR Code

Performance and Flow Characteristics of a Forward Swept Propeller Fan

전향 스윕 프로펠러 홴의 성능 및 유동특성

  • 김진권 (서울대학교 터보동력기계연구센터) ;
  • 강신형 (서울대학교 기계항공공학부)
  • Published : 2000.01.01

Abstract

Performance and flow characteristics of a small forward swept propeller fan for home refrigerators are studied experimentally. An unusual discontinuity is observed in the performance curve of the fan. Mean flow fields measured with as-hole Pitot probe reveal that the flow is axial at the high flow rate and radial at the low flow rate. The flow structure changes abruptly across the discontinuity. Unsteady flow measurements with a set of hot-wire probes indicate that near the discontinuity a single-cell stall rotates at 40% speed of the fan speed, while away from the discontinuity the flow shows periodic variation corresponding to the blade passage frequency. Phase-lock averaged flow fields measured with a triple-sensor hot-wire probe show that there appears radially inward flow over the pressure side of the blade and the outward passage flow over the tip.

Keywords

References

  1. Fukano, T., Kodama, Y., and Takamatsu, Y., 1978, 'Noise generated by low pressure axial flow fans, III: Effects of rotational frequency, blade thickness and outer blade profile,' J. Sound and Vibration, Vol. 56(2), pp.261-277 https://doi.org/10.1016/S0022-460X(78)80020-0
  2. 삼성전자,1995, 내부연구보고서
  3. 강신형, 김진권, 이승배, 1996, '뒷판을 가진 소형 프로펠러 홴의 성능 및 유동특성,' 대한기계학회논문집 (B), 제 20 권, 제 4 호, pp. 1491-1500
  4. AMCA, 1987, Fan Application Manual, Publication 201, Fans and Systems, AMCA, Illinois, pp. 2-6
  5. 김진권, 1998, '전향 스윕 프로펠러 홴의 성능 및 유동특성,' 서울대학교 박사학위 논문, pp. 11-20, 136
  6. 김진권, 강신형, 1997, '5공프로브의 전 각도 범위 압력계수 지도와 새로운 보정계수,' 대한기계학회 논문집 (B), 제 21 권, 제 11 호, pp. 1437-1448
  7. 김진권, 강신형, 1999, '삼직교 열선유속계의 간편한측정법 개발,' 대한기계학회 논문집 (B), (채택)
  8. Baumeister, Jr., T., 1935, FANS, McGraw-Hill, New York, p. 31
  9. Greitzer, E. M., 1981, 'The Stability of Pumping Systems - The 1980 Freeman Scholar Lecture,' J. Fluids Engineering, ASME Transcations, Vol. 103, pp. 193-242
  10. Tanaka, S. and Murata S., 1994, 'Scale Effects in Cross-Flow Fans (Effects of Fan Dimensions on Flow Details and the Universal Representation of Performances),' JSME International Journal Series B, Vol. 38, No. 3, pp.388-397
  11. Goto, A., 1998, 'Stall Margin Improvement Using Circumferential High-Speed Fluid Injections,' ISROMAC-7, pp. 1123-1138