Application of Spatial Modulation of Magnetization to Cervical Spinal Stenosis for Evaluation of the Hydrodynamic Changes Occurring in Cerebrospinal Fluid

  • Kwang-Hun Lee (Department of Diagnostic Radiology, Research Institute of Radiological Science, Yonsei University College of Medicine) ;
  • Tae-Sub Chung (Department of Diagnostic Radiology, Research Institute of Radiological Science, Yonsei University College of Medicine) ;
  • Tae Joo Jeon (Department of Diagnostic Radiology, Research Institute of Radiological Science, Yonsei University College of Medicine) ;
  • Young Hwan Kim (Department of Diagnostic Radiology, Inje University college of Medicine Sanggye Baik Hospital) ;
  • Daisy Chien (Siemens Ltd., Medical Division) ;
  • Gerhard Laub (Siemens AG.)
  • Received : 1999.10.19
  • Accepted : 2000.02.09
  • Published : 2000.03.31

Abstract

Objective: To evaluate the hydrodynamic changes occurring in cerebrospinal fluid (CSF) flow in cervical spinal stenosis using the spatial modulation of magnetization (SPAMM) technique. Materials and Methods: Using the SPAMM technique, 44 patients with cervical spinal stenosis and ten healthy volunteers were investigated. The degree of cervical spinal stenosis was rated as low-, intermediate-, or high-grade. Low-grade stenosis was defined as involving no effacement of the subarachnoid space, intermediate-grade as involving effacement of this space, and high-grade as involving effacement of this space, together with compressive myelopathy. The patterns of SPAMM stripes and CSF velocity were evaluated and compared between each type of spinal stenosis and normal spine. Results: Low-grade stenosis (n = 23) revealed displacement or discontinuity of stripes, while intermediate- (n = 10) and high-grade (n = 11) showed a continuous straight band at the stenotic segment. Among low-grade cases, 12 showed wave separation during the systolic phase. Peak systolic CSF velocity at C4-5 level in these cases was lower than in volunteers (p < .05), but jet-like CSF propulsion was maintained. Among intermediate-grade cases, peak systolic velocity at C1-2 level was lower than in the volunteer group, but the difference was not significant (p > .05). In high-grade stenosis, both diastolic and systolic velocities were significantly lower (p < .05). Conclusion: Various hydrodynamic changes occurring in CSF flow in cervical spinal stenosis were demonstrated by the SPAMM technique, and this may be a useful method for evaluating CSF hydrodynamic change in cervical spinal stenosis.

Keywords

Acknowledgement

We thank Dong Kee Kim, PhD for his assistance with statistics.

References

  1. Di Chiro G. Movement of the cerebrospinal fluid in human beings. Nature 1964;204:290-291  https://doi.org/10.1038/204290a0
  2. Di Chiro G. Observations on the circulation of the cerebrospinal fluid. Acta Radiol 1966;5:988-1002  https://doi.org/10.1177/02841851660050P242
  3. Du Boulay GH. Pulsatile movements in the CSF pathways. Br J Radiol 1966;39:255-262  https://doi.org/10.1259/0007-1285-39-460-255
  4. Du Boulay GH, O Connell J, Currie J, Bostick T, Verity P. Further investigations on pulsatile movements in the cerebrospinal fluid pathways. Acta Radiol 1972;13:496-523  https://doi.org/10.1177/02841851720130P205
  5. Lane B, Kricheff II. Cerebrospinal fluid pulsations at myelography: a videodensitometric study. Radiology 1974;110:579-587  https://doi.org/10.1148/110.3.579
  6. Nitz WR, Bradley WG, Watanabe AS. Flow dynamics of cerebrospinal fluid: assessment with phase-contrast velocity MR imaging performed with retrospective cardiac gating. Radiology 1992;183:395-405  https://doi.org/10.1148/radiology.183.2.1561340
  7. Feinberg DA. Modern concepts of brain motion and cerebrospinal fluid flow. Radiology 1992;185:630-632  https://doi.org/10.1148/radiology.185.3.1438734
  8. Maier SE, Hardy CJ. Brain and cerebrospinal fluid motion: real-time quantification with M-mode MR imaging. Radiology 1994;193:477-483  https://doi.org/10.1148/radiology.193.2.7972766
  9. Axel L, Dougherty L. MR imaging of motion with spatial modulation of magnetization. Radiology 1989;171:841-845  https://doi.org/10.1148/radiology.171.3.2717762
  10. Wayte SC, Redpath TW, Beale DJ. Magnetic resonance imaging of pulsatile cerebrospinal fluid flow by spatial modulation of magnetization. Br J Radiol 1992;65:495-501  https://doi.org/10.1259/0007-1285-65-774-495
  11. Wayte SC, Sakas DE, Beale DJ. Spatial modulation of magnetization in the study of CSF dynamics: implications for neurosurgical practice. (abstr). In: Book of abstracts: Society of Magnetic Resonance in Medicine 1996. New York, New York: Society of Magnetic Resonance in Medicine, 1992;640 
  12. Schroth G, Klose U. Cerebrospinal fluid flow I. Neuroradiology 1992;35:1-9  https://doi.org/10.1007/BF00588270
  13. Greitz D, Franck A, Nordell B. On the pulsatile nature of intracranial and spinal CSF-circulation demonstrated by MR imaging. Acta Radiol 1993;34:321-328  https://doi.org/10.1177/028418519303400403
  14. Quencer RM, Donovan Post MJ, Hinks RS. Cine MR in the evaluation of normal and abnormal CSF flow: intracranial and intraspinal studies. Neuroradiology 1990;32:371-391  https://doi.org/10.1007/BF00588471
  15. Sherman JL, Nassanx PY, Citrin CM. Measurements of the normal cervical spinal cord on MR imaging. AJNR 1990;11:369-372 
  16. Schellinger D, LeBihan D, Rajan SS, et al. MR of slow CSF flow in the spine. AJNR 1992;13:1393-1403 
  17. Reul J, Gievers B, Weis J, Thron A. Assessment of the narrow cervical spinal canal: a prospective comparison of MRI, myelography and CT-myelography. Neuroradiology 1995;37:187-191 https://doi.org/10.1007/BF01578255