금속-PDC 착물의 음이온교환 수지 상 흡착에 의한 흔적량 코발트와 니켈의 동시 예비농축 및 정량

Preconcentration and Determination of Trace Cobalt and Nickel by the Adsorption of Metal-PDC Complexes on the Anion-Exchange Resin Suspension

  • 한철우 (고려대학교 대학원 소재화학과) ;
  • 인교 (고려대학교 대학원 소재화학과) ;
  • 최종문 (동해대학 소방안전관리과) ;
  • 김선태 (한국과학기술연구원 특성분석센터) ;
  • 김영상 (고려대학교 대학원 소재화학과)
  • Han, Chul-Woo (Department of Chemistry, Korea University) ;
  • In, Gyo (Department of Chemistry, Korea University) ;
  • Choi, Jong-Moon (Department of Fire Protection & Security Management, Tong-Hae College) ;
  • Kim, Sun Tae (Advanced Analysis Center, Korea Institute of Science and Technology) ;
  • Kim, Young-Sang (Department of Chemistry, Korea University)
  • 투고 : 2000.07.28
  • 발행 : 2000.10.25

초록

물 시료에 존재하는 극 미량의 니켈과 코발트를 착물로 형성시켜 이온 교환수지 서스펜션에 흡착시켜 분리 농축하여 정량하는 방법을 연구하였다. 리간드로 APDC (ammonium pyrrolidine dithiocarbamnate)를 사용하여 극 미량 이온들을 착물로 형성시켜 농축한 다음, 전열 원자흡수 분광광도법으로 정량하였다. 이때 착물 형성을 위한 수용액의 pH와 착화제인 APDC의 양, 흡착을 위한 이온교환 수지의 종류 및 저어주는 시간, 역 분산에 사용하는 산의 종류 및 농도, 초음파 진동시간 등의 실험조건들을 최적화 하였다. 시료용액의 pH를 5로 조절하고 APDC의 양을 몰 비로 분석원소 전체의 430배 이상 첨가하여 코발트와 니켈을 정량적으로 착물을 형성시켰다. 이온교환 수지는 음이온 형태의 Dowex 2-X8이 우수하였다. pH를 조절한 시료용액, 리간드 및 수지 서스펜션을 혼합하고 1분간 저어주어 흡착을 완전하게 하였다. 역 분산을 위해서는 0.1 M 염산이 가장 좋았고, 이때 막 필터로 거른 교환 수지를 초음파 진동기에서 7분간 진동하면 충분하였다. 팔라듐을 염산과 함께 사용하면 매트릭스를 개선하여 재현성과 감도가 개선되었다. 바탕흡수 신호표준편차의 세배에 해당하는 검출한계는 Co 0.36 ng/mL, Ni 0.27 ng/mL로 극미량 검출이 가능하였고 시료에 일정량 첨가한 분석원소의 회수율은 각각 99-102%와 100-105% 이었다.

A determination method of trace nickel and cobalt in water samples was studied and developed by adsorbing their complexes on ion exchange resin suspension. The analytical ions were formed as complexes with a ligand of APDC (ammonium pyrrolidinedithiocarbamate) and adsorbed on anion exchange resin of Dowex 2-X8. After the suspension was filtered out with membrane filter, the complexes were dissolved in HCl solution by an ultrasonic vibrator for ET-AAS determination. Several conditions were optimized as followings. pH of sample solution: 5.0, amount of ligand APDC: more than 430 times in mole ratio, the type and concentration of acid: 0.1 M HCl, and vibration time: 7 minutes. The addition of palladium in the HCl solution could improve the reproducibility and sensitivity by a matrix modification in the absorbance measurement. This procedure was applied for the analysis of three kinds of real water samples. The detection limits equivalent to 3 times standard deviation of blank were Co 0.36 ng/mL and Ni 0.27 ng/mL and recoveries in spiked samples were 99-102% for cobalt and 100-105% for nickel.

키워드

참고문헌

  1. J. Korean Chem. Soc. v.40 no.12 Y.J. Jung;J.M. Choi;H.S. Choi;Y.S. Kim
  2. Spectrochim. Acta v.119 no.67 P. Fodor;R.M. Barnes
  3. Anal. Sci. & Tech. v.2 no.1 Y.S. Kim;J.M. Choi;S.J. Park
  4. Analyst v.115 no.23 O. Kunio;M. Masea;Y. Fumihiko;N. Isoshi;I. Ryoei
  5. Anal. Chem. v.65 no.1273 O. Tadio;T. Yasuhiro;S. Akio
  6. Anal. Sci. v.14 no.523 A. Katsunori;C. Xueze;O. Tamotsu;N. Isoshi;O. Kunio
  7. Anal. Sci. v.13 no.41 S. Junichi;M. Shinichi
  8. J. Korean Chem. Soc. v.40 no.2 H.S. Choi;J.M. Choi;Y.S. Kim
  9. Anal. Sci. & Tech. v.8 no.4 Y.S. Kim;J.M. Choi;Y.M. Kim
  10. J. Korean Chem. Soc. v.39 no.3 J.M. Choi;H.S. Choi;Y.S. Kim