Degradation Evaluation of 1Cr-lMo-0.25V Steel by Measuring Reversible Magnetic Permeability

가역 투자율 측정에 의한 1Cr-1Mo-0.25V 강의 열화도 평가

  • 유권상 (한국표준과학연구원 전자기표준부) ;
  • 김용일 (한국표준과학연구원 산업측정표준부) ;
  • 남승훈 (한국표준연구원 물질량표준부) ;
  • 유광민 (한국표준과학연구원 전자기표준부) ;
  • 조육 (한남대학교 물리학과) ;
  • 손대락 (한남대학교 물리학과)
  • Published : 2000.10.30

Abstract

The integrity of the turbine rotors can be assessed by measuring reversible permeability and Vickers hardness of the aged rotors at service temperature. The measurement system of reversible permeability, which measured by applied alternating perturbing magnetic field, was constructed in order to evaluate material degradation, nondestructively. The test specimen was 1Cr-1Mo-0.25V steel used widely for turbine rotor material, and the specimens were prepared by the isothermal heat treatment at $630\;^{\circ}C$. The reversible permeability of the test materials were measured at room temperature. The peak interval of reversible permeability and Vickers hardness decreased with the increase of degradation. The degradation of test material may be determined nondestructively by the lineality of Vickers hardness and the peak interval of reversible permeability.

고온에서 운용 중인 설비의 안전성을 평가하기 위해서는 사용기간동안 열화된 재료의 물성을 측정하여야 한다. 실제 사용되고 있는 화력발전소 터빈의 로터에서 열화도가 다른 여러 종류의 시편을 입수하기 어렵기 때문에, 터빈 로터재로 널리 사용되고 있는 1Cr-1Mo-0.25V 강을 인공열화시켜 시편으로 사용하였다 열화도의 비파괴적 평가를 위하여 교류 섭동 자기장을 인가하여 가역 투자율을 측정하는 자기적 방법을 사용하였다. 열화도의 증가에 따라 경도와 가역 투자율 피크 사이의 간격은 감소하였는데, 경도와 가역 투자율 피크 간격과의 선형관계를 이용하여 비파괴적으로 터빈 로터강의 열화도를 평가할 수 있는 기초를 마련하였다.

Keywords