A Study on Methohs Reducing Groundwater Contamination Around Kimpo Landfill

김포매립지 주변 지하수오염 확산 저감 방법 연구

  • Published : 2000.03.01

Abstract

In order to reduce the groundwater contamination around the Kimpo landfill in Korea by the leakage of the leachate within it, The method establishing 5 sets of Radial Collector Well Laterals(RCWLs) within the landfill, the method utilizing the wells dewatering the condensed water, the method establishing an interception wall to the 2nd layer at the circumference of the landfill and 22 sets of RCWLs within it, and the method establishing an interception wall to the 3rd layer and 40 sets of RCWLs were studied. Hydraulic parameters were measured for this study and then the groundwater flow and contaminant transport systems around the Kimpo landfill were analyzed with the MODFLOW and MT3D models. Conclusively, the method establishing an interception wall to the 2nd layer and 22 sets of RCWLs was evaluated as the most stable and economical option to reduce groundwater contamination concentration below drinking water standards.

김포매립지 내의 침출수의 누출에 의한 매립지 주변의 지하수오염을 감소시키기 위해, 매립지 내부에 5조의 수평방사형 수집정(Radial Collector Well Laterals(RCWL))을 설치하는 방법, 응축수 배제정을 이용하는 방법, 매립지의 주변에 차수벽을 2층까지 설치하고 매립지 내부에 22조의 RCWL을 설치하는 방법, 그리고 매립지 둘레에 차수벽을 3층까지 설치하고 매립지 내부에 40조의 RCWL을 설치하는 방법 등을 연구했다. 이를 위해, 수리파라미터를 측정하고, MODFLOW과 MT3D 모델을 사용하여, 김포매립지주변의 지하수 이동과 오염물질 이동체계를 분석했다. 분석결과 차수벽을 2층까지 그리고 2조의 RCWL을 설치하는 방법이 지하수 오염농도를 먹는물 수질기준까지 감소시킬 수 있는 가장 경제적인 방법으로 평가되었다.