Abstract
Ground Penetrating Radar (GPR) with 1 GHz antenna has been used to locate a steel bar embedded inside laboratory-prepared mortar specimens. Four mortar specimens are made with the dimensions of 100 cm (length) x 100 cm (width) x 14 cm (depth). One specimen had no bars and the other three specimens had a Dl9 steel bar at 4, 6. and 8 cm depth. As a part of the experimental work, the dielectric constants of mortar specimens are measured during curing. As the curing time increased. the dielectric constant decreased with decreasing moisture content inside the specimen. The steel bar embedded inside mortar specimens has been successfully identified in all three cases. The results using signal processing scheme developed in this study significantly improved the output of a commercially available radar system.