Abstract
This study is to investigate for the frost resistance of high-strength concrete using finely ground granulated blast-furnace slag with experimental parameters, such as water/binder ratio, replacement proportion of granulated blast-furnace slag, air content and methods of curing. The high-strength concrete using granulated blast-furnace slag is effective to resist frost and decrease scaling. The more increasable replacement proportion of granulated blast-furnace slag is, the better the effect is. The high-strength concrete using granulated blast-furnace slag needs hydrating adequately to prevent deterioration by drying in the early curing period. The micro structure of high-strength concrete, increased to the pore number with diameter of 0.03~0.1mm, is changed by using granulated blast-furnace slag, but is presented differently according to water/binder ration and replacement proportion of granulated blast-furnace slag.