Abstract
In precision chemical application increment of biological efficacy with less chemical is the virtue. spraying rate and droplet size is closely related to biological efficacy. this study was performed to develope a spray-control-system that could control spraying rate and droplet size independently. Twin-fluid nozzles were selected and tested to certify if the nozzles were suitable for the objective of this study. Characteritics of the nozzles i.e., spraying rte and droplet size change u8nder the changes of spraying pressure and air pressure were statistically modeled. The model had I to 1 matching property between dependent variables and independent variables. Using the property and the model, inverse relationship could be determined between variables. A feedback spray control system was developed and tested with predetermined error of 5 % in pressure. The system showed 4 % error in spraying rate and 9 % error in droplets size. Performance of the system could be upgraded by fine tuning but, in practical sense keeping air pressure in the field sprayer was the bottle neck of commercialization of the spray system.