A Study on the AC Interfacial Breakdown Properties of the Interface between Epoxy/EPDM with Variation of the Spread Oil

도포된 오일의 변화에 따른 Epoxy/EPDM 계면의 교류 절연파괴 특성에 관한 연구

  • Published : 2000.08.01

Abstract

Many successful developments and microscopic studies have been made on the high quality insulating materials. However, a little attention have given to the macroscopic interface in HV(High Voltage) insulating systems. In this study, AC interfacial breakdown strength and V-t characteristic of the interface between Epoxy/EPDM(ethylene propylene diene terpolymer) are investigated. Electrode system is designed to reduce the charges from electrodes and to have the tangential potentials along the interface between Epoxy/EPDM by FEM(finite elements method). The AC breakdown strength is observed when HV is given to the interface. It is shown that AC interfacial breakdown strength is improved by increasing interfacial pressure and oiling. In particular, it was saturated at certain interfacial pressure level. V-t characteristic is able to extend to the life time of the interface between Epoxy/EPDM. Oiling also plays a good roll in prolongation of the life time.

Keywords

References

  1. Katsumi Uchida et al., 'Study on Detection for the Defects of XLPE Cable Lines' IEEE Trans. on Power Delivery, Vol. 11, No.2, pp. 663-668, April 1996 https://doi.org/10.1109/61.489320
  2. Yutaka Nakanishi et al., 'Development of Prefabricated Joint for 275-kV XLPE Cable' IEEE Trans. on Power Delivery, Vol. 10, No.3, pp. 1139-1146 July 1995 https://doi.org/10.1109/61.400890
  3. D. Fournier and L. Lamarre, ' Effect of pressure and length on interfacial breakdown between two dielectric surfaces,' Conference Record of the 1994 IEEE International Symposium on Electrical Insulation, Baltimore, MD, USA, pp. 270-272 June, 7-10, 1992 https://doi.org/10.1109/ELINSL.1992.247004
  4. M. Nagao et al., 'Model Specimens for Testing Interfacial Electrical Insulating Properties in EHV Extruded Cable Splices and Preliminary Results -Specimen with sphere electrode (EPR-XLPE Interface)-', CIGRE WG. 15-10, 1999
  5. Chinh Dang, 'Effect of Surface Condition on the Breakdown strength of Various Dielectric Interface' 1995 International Symposium on Electrical Insulating Materials, pp. 189-192, 1995 https://doi.org/10.1109/ISEIM.1995.496540
  6. J. D. Smith and L. L. Hatfield, 'Measurements of the effects of surface roughness on flashover,' 1988 Annual Report of Conference on Electrical Insulation and Dielectric Phenomena, Ottawa, Ontario, Canada, pp. 47-52 Oct. 16-20, 1988 https://doi.org/10.1109/CEIDP.1988.26307
  7. 日本 電氣學會 技術 報告 固體 絶緣材料の界面 效果 調査 專門 委員會(編), '固體 絶緣材料の界面 效果,' pp.6, 106-122, April 1994
  8. H. Nakanishi et al., 'Stability of interfaces for prefabricated joint' 1993 IEEJ National Convention No. 1601, pp. 12, 1993
  9. G. C. Stone, 'The Statistic of Aging Models and Practical Reality' IEEE Trans. on Electrical Insulation, Vol. 28 No. 5, pp. 716-728, October 1993 https://doi.org/10.1109/14.237738
  10. P. Andersen et al., 'Development of a 420kV XLPE Cable Syetem for the Metropolitan Power Projection in Copenhagen', CIGRE, WG. 21-201, 1996