하이브리드 알고리즘을 응용하여 안전도제약을 만족시키는 최적전력조류

Security Constrained Optimal Power Flow by Hybrid Algorithms

  • 발행 : 2000.06.01

초록

This paper presents a hybrid algorithm for solving optimal power flow(OPF) in order to enhance a systems capability to cope with outages, which is based on combined application of evolutionary computation and local search method. The efficient algorithm combining main advantages of two methods is as follows : Firstly, evolutionary computation is used to perform global exploitation among a population. This gives a good initial point of conventional method. Then, local methods are used to perform local exploitation. The hybrid approach often outperforms either method operating alone and reduces the total computation time. The objective function of the security constrained OPF is the minimization of generation fuel costs and real power losses. The resulting optimal operating point has to be feasible after outages such as any single line outage(respect of voltage magnitude, reactive power generation and power flow limits). In OPF considering security, the outages are selected by contingency ranking method(contingency screening model). The OPF considering security, the outages are selected by contingency ranking method(contingency screening model). The method proposed is applied to IEEE 30 buses system to show its effectiveness.

키워드

참고문헌

  1. H.W. Dommel &W.F. Tinney, 'Optimal Power Flow Solution', IEEE Trans. PAS-87, 1968, pp.1866-1876 https://doi.org/10.1109/TPAS.1968.292150
  2. D.I. Sun, B. Ashley, B. Brewer, A Hushes, W. F. Tinney, 'Optimal Power Flow by Newton Approach,' IEEE Trans. on PAS, Vol. 103, No. 10, pp2864-2880,1984 https://doi.org/10.1109/TPAS.1984.318284
  3. E. Hobson, 'Network Constrained Reactive Power Control Using Linear Programming', IEEE Trans. on Power PAS, Vol. 99, pp868-877, 1980 https://doi.org/10.1109/TPAS.1980.319715
  4. A. Urcaneta, 'A Hybrid Genetic Algorithm for Optimal Reactive Power Planning Based Upon Successive Linear Programming IEEE Trans. on Power System, Vol.9, Aug. 1994, pp1327-1336 https://doi.org/10.1109/59.336133
  5. J. S. Lipowski, C. Charalambous, 'Solution of Optimal Load Flow Problem by Modified Recurcive Quadratic Programming Method', Proceeding of IEE, Vol. 5, No. 3, pp691-711, 1990
  6. R.C. Burchett, H. H. Happ, D. R. Virerath, 'Quadratically Convergent Optimal Power Flow,' IEEE Trans. on PAS, Vol. 103, No. 11, pp3267-3276,1984 https://doi.org/10.1109/TPAS.1984.318568
  7. R.R. shoult, D.T. Sun, 'Optimal Power Flow Based upon P-Q Decomposition,' IEEE Trans. on PAS, Vol. 101, No. 2, pp397-405, 1982 https://doi.org/10.1109/TPAS.1982.317120
  8. J. Momoh, S.X. Guo, E.C. Ogbuobiri & R. Adapa, 'The Quadratic Interior Point Method Solving Power Systems Optimisation Problems', IEEE Trans. on Power Systems, Vol. 9, Aug. 1994, pp1327-1336 https://doi.org/10.1109/59.336133
  9. J. R. McDonnell, D. B. Fogel, 'Evolutionary programming Ⅳ', MIT Press, 1995
  10. K. P. Wong, 'Evolutionary Programming based Optimal Power Flow Algorithm', IEEE Trans. on Power Systems, Vol. 14, No. 4, Nov. pp1245-1250, 1999 https://doi.org/10.1109/59.801880
  11. K.P. Wong, and Y.W. Wong, 'Genetic and genetic/simulated-annealing approaches to economic dispatch', IEE Proc. Gen. Trans. & Distrib, Vol. 141, No.5, 1994, pp.507-513 https://doi.org/10.1049/ip-gtd:19941354
  12. G. C. Ejebe, B. F. Wollenberg, 'Automatic Contingency Selection', IEEE Trans. on PAS, Vol. PAS-98, No. 1, pp97-103, 1979 https://doi.org/10.1109/TPAS.1979.319518
  13. 김규호, 유석구, '상정사고를 고려한 전압·무효전력 예방제어', 대한전기학회 논문지, 제 44권 9호, pp1141-1149, 1995
  14. C.T. Lawrence & A.L. Tits, 'Nonlinear Equality Constraints in Feasible Sequential Quadratic Programming,' Optimization Methods and Software 6(1996), 265-282 https://doi.org/10.1080/10556789608805638