Abstract
The novel integration method with programmable high-pass filter is suggested in order to solve the problem of integration for stator flux estimation in a stator flux oriented direct vector controlled induction motor drive system. The dc offset in a pure integrator is eliminated using high-pass filter with fixed time constant, and then time constant of programmable high-pass filter is controlled with a inverter frequency for integration in a wide frequency range, considering phase lag and attenuation due to both the hardware low-pass filter and high-pass filter. The proposed method is verified with the experimental results implemented by 32-bit DSP.