Abstract
There was extreme improvement in the processing result of weld toe, but there is possibility that the fatigue failure occurs from the weld root part where the fatigue strength became low relatively. This study did the fatigue test at the cross rib specimens which implemented a partial penetration weld to improve the fatigue strength of the weld root part. As a result of the fatigue test of the partial penetration weld and the fillet weld specimens, almost the same fatigue strength appeared. Because the fatigue failure began from toe, there was not a reinforcement effect in the weld root part by the partial penetration weld. So, it examined fatigue strength at the partial penetration welding specimens which processed toe to stop the fatigue failure of toe part. As a result, there was big fatigue strength improvement from the partial penetration weld than the fillet weld. Therefore, if fatigue crack occurrence can be restrained from toe, it thinks that the fatigue strength of the root part can improve by the partial penetration weld, after all, it thinks that the overall fatigue life can improve.
본 연구는 용접지단부의 후처리 결과, 상대적으로 피로강도가 낮아진 용접루트부에 초점을 맞추었다. 용접루트부의 피로강도를 향상시키기 위하여 부분용입용접을 실시한 십자 리브 시험체와 보통의 필렛용접이음 십자 리브 시험체를 대상으로 피로시험을 행하였다. 그 결과, 부분용입용접을 한 시험체이더라도 용접그대로인 시험체의 경우는 보통의 필렛용접이음과 거의 동등한 피로강도를 보였다. 이것은 피로파괴가 지단부로부터 시작되었기 때문에 용접루트부의 보강책인 부분용입용접의 효과가 나타나지 않았다고 생각된다. 이에, 지단부의 피로파괴를 막기 위해 지단부를 후처리시킨 부분용입용접이음 시험체를 대상으로 피로시험을 한 결과, 보통의 필렛용접이음보다 상당한 피로강도 향상을 보였다. 그러므로 본 연구는 지단부로부터 피로균열 발생을 억제한다면, 부분용입용접이음으로 루트부의 피로강도를 향상시켜, 결국 전체적인 파단수명을 향상시킬 수 있을 것으로 생각한다.