DOI QR코드

DOI QR Code

볼 엔드밀링에서 열전대를 이용한 절삭온도 측정법

Measurement Technique of Cutting Temperatures Using Implanted Thermocouples in Ball End-Milling


초록

In this paper, the measurement technique of cutting temperatures of shear zone using implanted thermocouples is proposed in ball end milling. K-type thermocouple implanted in the hole of workpieces is directly cut in order to measure temperatures of the shear zone in cutting process. Experiments are performed for a nickel based superalloy(Inconel 718) using a ball nose end mill. The results show that the cutting temperature in shear zone is about 3200C at the cutting speed of 90m/min with dry.

키워드

참고문헌

  1. Wang, Z. Y., Rajurkar K. P. and Fan, J., 1996, ' Turning T1-6AA1-4V Alloy with Cryogenic Cooling,' Transactions of NAMRI/SME, Volume X X IV, p. 3
  2. Lezanski P., Shaw M. C.,1990, ' Tool Face Temperatures in High Speed Milling,' Transactions of the ASME, Vol. 112, p. 132
  3. Kovacevic R., Cherukuthota C. and Mazurkiewicz M., 1995, ' High Pressure Water jet Cooling/Lubrication to Improve Machining Efficiency in Milling,' Int. J. Mach. Tools Manufact, Vol. 35, No. 10, pp. 1459 https://doi.org/10.1016/0890-6955(95)00128-K
  4. Schultz H., Hock St., 1995 ' High-Speed Milling of Dies and Moulds-Cutting Conditions and Technology,' Annals of the CIRP Vol. 44, pp. 35 https://doi.org/10.1016/S0007-8506(07)62270-7
  5. 양민양, 1997, 절삭가공-이론과 실제, 청문각
  6. Ding, Y. and Hong S. Y., 1995, ' A Study of the Cutting Temperatures in Machining Processes cooled by Liquid Nitrogen,' Technical Papers, The North Americal Manufacturing Research Institution of SME, p. 114