서변 가압장에서 수격현상 완화에 대한 연구

Simulation of Water Hammer Mitigation at Seobyun Pumping Station

  • 김상현 (부산대학교 공과대학 환경공학과) ;
  • 박남식 (동아대학교 공과대학 토목공학과) ;
  • 정봉석 (부산대학교 공과대학 환경공학과) ;
  • 이동훈 (부산대학교 공과대학 환경공학과)
  • 발행 : 1999.03.15

초록

A simulation of water hammer, introduced by abruptly varied motion of a pumping machine, was performed at a one of typical pumping station in Korea. Impact of hydraulic structure such as check valve, pressure relief valve and air valve in mitigating water hammer effect was estimated gradually. Method of characteristic was employed for the effective calculation of discharge and head. The relationship between various hydraulic structures and flow was properly integrated on the base of the method of characteristic. The methodology in this approach can provide significant contribution in decision making procedure for the design of hydraulic structure at a typical pumping station in Korea.