Abstract
The spectrophotometric determination of Al(III) with thorin have been investigated. The optimum condition of pH, concentration of ligand and surfactant, and stability were evaluated. The thorin ligand offers selective separation of Al(III) from sample solution containing Fe(III), Ni(II), Cu(II), Pb(II) and Cu(II). Various surfactants were tested and Triton X-100 showed the best stability and the maximum absorbance in an aqueous solution of Al(III)-Thorin-Triton X-100 complex appears about 526 nm. The method was applied for the determination of Al(III) in mixed sample solution. Separation and preconcentration was performed with a short column filled with resorcinol-formaldehyde resin. Control of the pH during the column operation is essential because the adsorption capacities are very sensitive to change in pH. Their separation was carried out in 0.2 M acetic acid-sodium acetate buffer solution (pH 4.5) and 1.0 M $HNO_3$media.
Al(III)-thorin 착물에 대한 분광학적 정량 방법을 연구하였다. pH, 리간드와 계면활성제의 농도 및 안정화 시간에 대한 최적 조건을 결정하였다. thorin 리간드는 Fe(III), Ni(II), Cu(II), Pb(II) 그리고 Co(II)를 포함한 시료용액으로부터 Al(III)을 선택적으로 분리할 수 있도록 해준다. 여러 계면활성제중에서 비이온성인 Triton X-100에서 가장 안정한 상태를 나타냈고 수용액 중에서 Al(III)-Thorin-Triton X-100 착물은 526 nm에서 최대 흡광도를 가진다. 이 방법은 혼합된 시료용액에서 Al(III)을 정량하는데 이용되었다. 그리고, 분리 및 예비농축과정은 resoreinol-fermaldehyde 수지로 채워진 컬럼을 이용하였다. 컬럼 단계에서 수지의 흡착 능력은 pH변화에 매우 민감하기 때문에 pH를 조절하는 것이 필수적이다. 분리과정은 0.2 M acetic acid-sodium acetate 완충용액 (pH 4.5)와 1.0 M $HNO_3$용액으로 이루어졌다.