Abstract
Trace cadmium was determined in urine by flame and nameless AAS. Inflame method, cadmium was extracted into MIBK from Cd-DDTC complex. In flameless method, samples were pretreated with 1%, Triton X-100. 1% $HNO_3$ and matrix modifier $Pd(NO_3)_2$. Analysis of cadmium was, performed at $450-750^{\circ}C$ ashing temperature by use of pyrocoated tubes. Results of analysis, flameless method superior in sample treatment and reproducibility to flame method and highest absorbance was obtained at $550^{\circ}C$ ashing temperature. 100 mg/L $Pd(NO_3)_2$ concentration. Proposed method were applied to the determination of cadmium in standard urine Lononorm-Metalle 3.
뇨중 미량 카드뮴 분석에 흑연로 장치가 부착된 원자흡수분광광도계(GFAAS)를 사용하였다. 불꽃분광법에서 시료는 회화하여 Na-DDTC로 착물을 형성한 후 MIBK로 추출하였으며, 비불꽃분광법에서는 1% Triton X-100과 1% $HNO_3$으로 5배 희석시킨 후 $Pd(NO_3)_2$를 매트릭스 개선제로 농도를 변화시키면서 회화 온도 $450-750^{\circ}C$에서 pyrocoated 흑연 튜브를 사용하여 분석하였다. 그 결과 불꽃분광법보다는 비불꽃분광법이 전처리가 간단하고 재현성있게 나타났으며, 비불꽃분광법을 이용한 경우 $Pd(NO_3)_2$ 100 mg/L을 사용하여 회화온도 $550^{\circ}C$에서 분석시 가장 높은 흡광도를 나타냈다. 본 분석법을 표준뇨인 Lononorm-Metalle 3 중의 카드뮴 분석에 적용하였다.