Buford Complex - A Case Report

Buford 복합체-1례 보고-

  • Park Jin- Young (Department of Orthopaedic Surgery, Dankook University College of Medicine) ;
  • Seo Hyun-Seog (Department of Orthopaedic Surgery, Dankook University College of Medicine) ;
  • Yoo Moon-Jib (Department of Orthopaedic Surgery, Dankook University College of Medicine)
  • 박진영 (단국대학교 의과대학 정형외과학교실) ;
  • 서현석 (단국대학교 의과대학 정형외과학교실) ;
  • 유문집 (단국대학교 의과대학 정형외과학교실)
  • Published : 1999.06.01

Abstract

The Buford complex is unusual variant of the glenohumeral joint. This complex is distinguished by a cord-like middle glenohumeral ligament that oriented directly form the superior labrum at the base of the biceps tendon and crosses the subscapularis tendon to insert on the humerus. There is no anterior-superior labral tissue present between this attachment and the mid-glenoid notch. This anatomical variation may lead the surgeon to confuse this complex with a sublabral hole, pathologic labral detachment, Bankart lesion or SLAP lesion. We report a case of Buford complex which was found incidentally during the operation of impingement syndrome with stiffness and treated with subacromial decompression only.

저자들은 충돌 증후군 진단하에 관절경적 견봉하 감압술 중 우연히 발견된 Buford 복합체를 가진 환자를 본 후, 술후 이 환자를 추시한 결과가 Buford 복합체가 없는 다른 환자의 경우와 크게 다르지 않은 것을 보고, 충돌 증후군의 증상을 보이는 환자에서 삭형 중 견와상완 인대와 전상방견와 순의 결여가 있는 경우 이 복합체가 술후 예후에 영향을 미치지 않는 것으로 결론을 내리고 이를 보고하는 바이다.

Keywords