Abstract
Seismic design code has been performed since 1988 in Korea, so it has not been applied to low-rise reinforced concrete buildings which had been built before 1988. Those building have been designed only for gravity loads based on non-seismic code, Therefore, even minor earthquake occurred, those buildings might have serious damages. In this paper, to investigate the behavior of low-rise reinforced concrete moment resisting frame which had been built in according to the building code of Korea that had been published before 1988, two type of 1/2 scaled exterior beam-column subassemblies which have non-seismic detailing based on the building code of Korea were constructed and tested with reversed cycling loading under the displacement control method. The special features of joint with non-seismic detailing is that there is no transverse reinforcement in the joint. In tests, cracks pattern, strength degradation, loss of stiffness, energy dissipation and the slippage of beam and column bars were investigated. Cracks did not occurred in the joint even seismic loading of 0.12g which is considered as peak ground acceleration in Korea was applied. And increasing seismic loading above 0.12g shear crack happened in the joint which have not transverse beam.
국내에서는 1988년부터 내진 규준이 시행되었으며, 따라서 그 이전에 지어진 저층 철근콘크리트 건물들은 내진 규준이 적용되지 않고 단지 축하중만을 고려하여 설계되었다. 그러므로 약한 지진이 발생하여도 이러한 건물들은 심한 피해를 입을 수 있다. 본 논문에서는, 내진 규준이 시행되기 이전에 지어진 비내진 저층 철근콘크리트 모멘트 저항 골조의 지진 발생시 거동과 피해를 알아보기 위하여, 실제 존재하는 비내진 건물 중 3층 철근콘크리트 라멘조 공공청사 건물의 외부 적합부를 교차보가 있는 것과 없는 것의 2종류를 1/2의 실물크기로 제작하고, 횡방향 변위 제어로 반복하중을 가하여 실험을 수행하였다. 비내진 접합부의 가장 큰 특징은 적합부내의 횡보강근이 없다는 것이다. 실험을 통하여 균열의 형태, 강도${\cdot}$강성의 저하, 에너지 소산 그리고 기둥과 보 부재의 철근 미끄러짐을 조사하였다. 국내에서 규정하고 있는 최대지반가속도인 0.12g크기의 횡방향 하중을 가력하였을 경우에는 균열이 발생하지 않았으나, 횡방향 하중을 0.12g이상으로 증가할수록 교차보가 없는 외부접합부에서 전단균열이 발생하였다.