A Study on the Improvement of Water-Leakage Detection Reliability in Local Heating System

지역난방배관의 누수감지 신뢰성 향상에 관한 연구

  • 신춘식 (부경대학교 제어계측공학과) ;
  • 안영주 (부경대학교 제어계측공학과) ;
  • 변기식 (부경대학교 제어계측공학과)
  • Published : 1999.03.01

Abstract

Local heating transportation pipe has sensor and return lines to detect water-leakage. There are impulse and resistance comparison measurement types for a water-leakage detection. The impulse type shows large detection error within a measurement range. Since the resistance comparison type can find a comparative accurate single water-leakage point in the measurement range of heating pipe, it has been used to detect water-leakages these days. However if the multi water-leakages are happened in the measurement range of transportation pipe. the resistance comparison type shows a detection error point by the parallel resistance between a detection sensor line and ground. But the detection error will be minimized by the divided transportation pipe loops. In this research, it suggests the design of remote controlled detection system which can divide a large pipe loop and a possible single water-leakage measurement process in each divided loops.

Keywords